SynthesisThe Cochrane database of systematic reviews2016
Implantable loop recorder versus conventional diagnostic workup for unexplained recurrent syncope.
Synthesis in The Cochrane database of systematic reviews, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 18 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
18 citing papers in PubMed, 1 synthesis or guideline pooled it, 54 citations in OpenAlex.
- Implantable loop recorder versus conventional diagnostic workup for unexplained recurrent syncope.The Cochrane database of systematic reviews · 2016Pooled it
- Trial
- A More Targeted and Selective Use of Implantable Loop Recorders Improves the Effectiveness of Syncope Units: A Single-Center Experience.Life (Basel, Switzerland) · 2024Article
- Value of Extended Arrhythmia Screening in Adult Congenital Heart Disease Patients.Arrhythmia & electrophysiology review · 2024Review
- Article
- Electrophysiology and arrhythmia care in Romania.Heart rhythm O2 · 2022Review
- Implantable loop recorder in unexplained palpitations or syncope: A randomised study among young patients with structurally normal heart.Medical journal, Armed Forces India · 2022Article
- The Syncope-Falls Index: a tool for predicting risk of syncope and complex falls in the older adult based on cumulative health deficits.QJM : monthly journal of the Association of Physicians · 2022Article
- An implantable loop recorder or smartphone based single-lead electrocardiogram to detect arrhythmia in adults with congenital heart disease?Frontiers in cardiovascular medicine · 2022Article
- Diagnostic value of implantable loop recorders in patients with unexplained syncope or palpitations.Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc · 2021Observational
- Cardioinhibitory syncope: from pathophysiology to treatment-should we think on cardioneuroablation?Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2020Review
- Cardiac Implantable Electronic Miniaturized and Micro Devices.Micromachines · 2020Review
- [Implantable ECG monitors].Herzschrittmachertherapie & Elektrophysiologie · 2020Review
- Implantable loop recorder in clinical practice.Journal of arrhythmia · 2019Review
- [Indications for loop recorder implantation for syncope].Herzschrittmachertherapie & Elektrophysiologie · 2018Review
- Use of implantable and external loop recorders in syncope with unknown causes.Journal of arrhythmia · 2017Review
- [Implantable loop recorder BioMonitor 2 (Biotronik)].Herzschrittmachertherapie & Elektrophysiologie · 2016Review
- [Implantable loop recorders in the diagnosis of syncope].Herzschrittmachertherapie & Elektrophysiologie · 2016Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 5 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe most recent syncope guideline recommends that implantable loop recorders (ILRs) are implanted in the early phase of evaluation of people with recurrent syncope of uncertain origin in the absence of high-risk criteria, and in high-risk patients after a negative evaluation. Observational and case-control studies have shown that loop recorders lead to earlier diagnosis and reduce the rate of unexplained syncopes, justifying their use in clinical practice. However, only randomised clinical trials with an emphasis on a primary outcome of specific ILR-guided diagnosis and therapy, rather than simply electrocardiogram (ECG) diagnosis, might change clinical practice.
objectivesTo assess the incidence of mortality, quality of life, adverse events and costs of ILRs versus conventional diagnostic workup in people with unexplained syncope. SEARCH
methodsWe searched the Cochrane Central Register of Controlled Trials (CENTRAL, Issue 3, 2015), MEDLINE, EMBASE, ClinicalTrials.gov and the World Health Organization (WHO) International Clinical Trials Registry Platform (ICTRP) Search Portal in April 2015. No language restriction was applied. SELECTION CRITERIA: We included all randomised controlled trials of adult participants (i.e. ≥ 18 years old) with a diagnosis of unexplained syncope comparing ILR with standard diagnostic workup. DATA COLLECTION AND ANALYSIS: Two independent review authors screened titles and abstracts of all potential studies we identified as a result of the literature search, extracted study characteristics and outcome data from included studies and assessed risk of bias for each study using the criteria outlined in the Cochrane Handbook for Systematic Reviews of Interventions. We contacted authors of trials for missing data. We analysed dichotomous data (all-cause mortality and aetiologic diagnosis) as risk ratios (RR) with 95% confidence intervals (CI). We used the Chi(2) test to assess statistical heterogeneity (with P < 0.1) and the I² statistic to measure heterogeneity among the trials. We created a 'Summary of findings' table using the five GRADE considerations (study limitations, consistency of effect, imprecision, indirectness and publication bias) to assess the quality of a body of evidence as it relates to the studies which contribute data to the meta-analyses for the prespecified outcomes. MAIN
resultsWe included four trials involving a total of 579 participants. With the limitation that only two studies reported data on mortality and none of them had considered death as a primary endpoint, the meta-analysis showed no evidence of a difference in the risk of long-term mortality between participants who received ILR and those who were managed conventionally at follow-up (RR 0.97, 95% CI 0.41 to 2.30; participants = 255; studies = 2; very low quality evidence) with no evidence of heterogeneity. No data on short term mortality were available. Two studies reported data on adverse events after ILR implant. Due to the lack of data on adverse events in one of the studies' arms, a formal meta-analysis was not performed for this outcome.Data from two trials seemed to show no difference in quality of life, although this finding was not supported by a formal analysis due to the differences in both the scores used and the way the data were reported. Data from two studies seemed to show a trend towards a reduction in syncope relapses after diagnosis in participants implanted with ILR. Cost analyses from two studies showed higher overall mean costs in the ILR group, if the costs incurred by the ILR implant were counted. The mean cost per diagnosis and the mean cost per arrhythmic diagnosis were lower for participants randomised to ILR implant.Participants who underwent ILR implantation experienced higher rates of diagnosis (RR (in favour of ILR) 0.61, 95% CI 0.54 to 0.68; participants = 579; studies = 4; moderate quality evidence), as compared to participants in the standard assessment group, with no evidence of heterogeneity. AUTHORS'
conclusionsOur systematic review shows that there is no evidence that an ILR-based diagnostic strategy reduces long-term mortality as compared to a standard diagnostic assessment (very low quality evidence). No data were available for short-term all-cause mortality. Moderate quality evidence shows that an ILR-based diagnostic strategy increases the rate of aetiologic diagnosis as compared to a standard diagnostic pathway. No conclusive data were available on the other end-points analysed.Further trials evaluating the effect of ILRs in the diagnostic strategy of people with recurrent unexplained syncope are warranted. Future research should focus on the assessment of the ability of ILRs to change clinically relevant outcomes, such as quality of life, syncope relapse and costs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.