Evidence map›Paper›PMID 27088236›Full record

ArticleNature materials2016

Bioresorbable silicon electronics for transient spatiotemporal mapping of electrical activity from the cerebral cortex.

Ki Jun Yu, Duygu Kuzum, Suk-Won Hwang, Bong Hoon Kim, Halvor Juul, Nam Heon Kim, Sang Min Won, Ken Chiang, Michael Trumpis, Andrew G Richardson and 17 more

Abstract read
In one paragraph

Article in Nature materials, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 141 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
141citing papers in PubMed, 1 pooled it
27.3field-weighted citation impact, top 1% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

141 citing papers in PubMed, 1 synthesis or guideline pooled it, 497 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Review
  13. Review
  14. Article
  15. Article
  16. Review
  17. Article
  18. Article
  19. Advances in Symbiotic Bioabsorbable Devices.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review
  20. Electrical Stimulation Therapy - Dedicated to the Perfect Plastic Repair.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025
    Review

81 more citing papers are in PubMed but not listed here.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

27 authors at 6 institutions in 2 countries.

Ki Jun Yu *Department of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
Duygu Kuzum *Department of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA.
Suk-Won HwangKU-KIST Graduate School of Converging Science and Technology, Korea University, Seoul 136-701, Republic of Korea.
Bong Hoon KimFrederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
Halvor JuulDepartment of Neurology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.
Nam Heon KimFrederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
Sang Min WonDepartment of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
Ken ChiangDepartment of Biomedical Engineering, Duke University, Durham, NC 27708, USA.
Michael TrumpisDepartment of Biomedical Engineering, Duke University, Durham, NC 27708, USA.
Andrew G RichardsonCenter for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, PA 19104, USA.
Huanyu ChengDepartment of Engineering Science and Mechanics, Penn State University, University Park, PA 16802, USA.
Hui FangFrederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
Marissa ThomsonDepartment of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA.
Hank BinkDepartment of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA.
Delia TalosDepartment of Neurology, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.
Kyung Jin SeoFrederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
Hee Nam LeeFrederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
Seung-Kyun KangFrederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
Jae-Hwan KimFrederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
Jung Yup LeeFrederick Seitz Materials Research Laboratory, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
Younggang HuangDepartment of Mechanical Engineering and Department of Civil and Environmental Engineering, Northwestern University, Evanston, IL 60208, USA.
Frances E JensenCenter for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, PA 19104, USA.
Marc A DichterCenter for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, PA 19104, USA.
Timothy H LucasCenter for Neuroengineering and Therapeutics, University of Pennsylvania, Philadelphia, PA 19104, USA.
Jonathan ViventiDepartment of Biomedical Engineering, Duke University, Durham, NC 27708, USA.
Brian LittDepartment of Bioengineering, University of Pennsylvania, Philadelphia, Pennsylvania 19104, USA.
John A RogersDepartment of Electrical and Computer Engineering, University of Illinois at Urbana-Champaign, Urbana, IL 61801, USA.
University of Illinois Urbana-Champaign · USUniversity of Pennsylvania · USDuke University · USKorea University · KRNorthwestern University · USPennsylvania State University · US

Funding

BRIAN INJURY TRAINING GRANTT32NS043126 · NINDS · UNIVERSITY OF PENNSYLVANIA · PI Douglas Hamilton Smith · 2003 to 2026
$5.9M
Training Program in Neuroengineering and MedicineT32NS091006 · NINDS · UNIVERSITY OF PENNSYLVANIA · PI Brian Litt · 2015 to 2026
$4.1M
NINDS NIH HHS T32 NS043126NINDS NIH HHS T32 NS091006
6 · The paper itself

Abstract

Bioresorbable silicon electronics technology offers unprecedented opportunities to deploy advanced implantable monitoring systems that eliminate risks, cost and discomfort associated with surgical extraction. Applications include postoperative monitoring and transient physiologic recording after percutaneous or minimally invasive placement of vascular, cardiac, orthopaedic, neural or other devices. We present an embodiment of these materials in both passive and actively addressed arrays of bioresorbable silicon electrodes with multiplexing capabilities, which record in vivo electrophysiological signals from the cortical surface and the subgaleal space. The devices detect normal physiologic and epileptiform activity, both in acute and chronic recordings. Comparative studies show sensor performance comparable to standard clinical systems and reduced tissue reactivity relative to conventional clinical electrocorticography (ECoG) electrodes. This technology offers general applicability in neural interfaces, with additional potential utility in treatment of disorders where transient monitoring and modulation of physiologic function, implant integrity and tissue recovery or regeneration are required.

Indexed as

Absorbable ImplantsBrain MappingElectrodes, ImplantedSiliconAnimalsBrain WavesCerebral CortexRatsSilicon

Identifiers

PMID27088236
PMCPMC4919903
OpenAlexW2342159388

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.