ArticleJournal of visualized experiments : JoVE2016
Whole-body Mass Spectrometry Imaging by Infrared Matrix-assisted Laser Desorption Electrospray Ionization (IR-MALDESI).
Article in Journal of visualized experiments : JoVE, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 18 citations in OpenAlex.
- Heterogeneous antiretroviral drug distribution and HIV/SHIV detection in the gut of three species.Science translational medicine · 2019Trial
- Optimizing neurotransmitter pathway detection by IR-MALDESI-MSI in mouse brain.Analytical and bioanalytical chemistry · 2024Article
- Time of acquisition and high spatial resolution mass spectrometry imaging.Journal of mass spectrometry : JMS · 2023Article
- The development and application of matrix assisted laser desorption electrospray ionization: The teenage years.Mass spectrometry reviews · 2023Review
- Recent Advances of Ambient Mass Spectrometry Imaging and Its Applications in Lipid and Metabolite Analysis.Metabolites · 2021Review
- Methods for Cryosectioning and Mass Spectrometry Imaging of Whole-Body Zebrafish.Journal of the American Society for Mass Spectrometry · 2020Article
- Determination of Optimal Electrospray Parameters for Lipidomics in Infrared-Matrix-Assisted Laser Desorption Electrospray Ionization Mass Spectrometry Imaging.Journal of the American Society for Mass Spectrometry · 2020Article
- Mass Spectrometry Imaging (MSI) of Fresh Bones using Infrared Matrix-Assisted Laser Desorption Electrospray Ionization (IR-MALDESI).Analytical methods : advancing methods and applications · 2019Article
- Internal Energy Deposition in Infrared Matrix-Assisted Laser Desorption Electrospray Ionization With and Without the Use of Ice as a Matrix.Journal of the American Society for Mass Spectrometry · 2019Article
- Systematic evaluation of repeatability of IR-MALDESI-MS and normalization strategies for correcting the analytical variation and improving image quality.Analytical and bioanalytical chemistry · 2019Article
- Article
- MSiReader v1.0: Evolving Open-Source Mass Spectrometry Imaging Software for Targeted and Untargeted Analyses.Journal of the American Society for Mass Spectrometry · 2018Article
- Infrared matrix-assisted laser desorption electrospray ionization mass spectrometry imaging analysis of biospecimens.The Analyst · 2016Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 1 institution in 1 country.
Funding
Abstract
Ambient ionization sources for mass spectrometry (MS) have been the subject of much interest in the past decade. Matrix-assisted laser desorption electrospray ionization (MALDESI) is an example of such methods, where features of matrix-assisted laser desorption/ionization (MALDI) (e.g., pulsed nature of desorption) and electrospray ionization (ESI) (e.g., soft-ionization) are combined. One of the major advantages of MALDESI is its inherent versatility. In MALDESI experiments, an ultraviolet (UV) or infrared (IR) laser can be used to resonantly excite an endogenous or exogenous matrix. The choice of matrix is not analyte dependent, and depends solely on the laser wavelength used for excitation. In IR-MALDESI experiments, a thin layer of ice is deposited on the sample surface as an energy-absorbing matrix. The IR-MALDESI source geometry has been optimized using statistical design of experiments (DOE) for analysis of liquid samples as well as biological tissue specimens. Furthermore, a robust IR-MALDESI imaging source has been developed, where a tunable mid-IR laser is synchronized with a computer controlled XY translational stage and a high resolving power mass spectrometer. A custom graphical user interface (GUI) allows user selection of the repetition rate of the laser, number of shots per voxel, step-size of the sample stage, and the delay between the desorption and scan events for the source. IR-MALDESI has been used in variety of applications such as forensic analysis of fibers and dyes and MSI of biological tissue sections. Distribution of different analytes ranging from endogenous metabolites to exogenous xenobiotics within tissue sections can be measured and quantified using this technique. The protocol presented in this manuscript describes major steps necessary for IR-MALDESI MSI of whole-body tissue sections.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.