Evidence map›Paper›PMID 27076562›Full record

ArticleJournal of the American Heart Association2016

Ischemic Stroke or Systemic Embolism After Transseptal Ablation of Arrhythmias in Patients With Cardiac Implantable Electronic Devices.

Malini Madhavan, Xiaoxi Yao, Lindsey R Sangaralingham, Samuel J Asirvatham, Paul A Friedman, Christopher J McLeod, Alan M Sugrue, Christopher V DeSimone, Peter A Noseworthy

Open access · goldAbstract read
In one paragraph

Article in Journal of the American Heart Association, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.9field-weighted citation impact, top 23% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.

  1. Pooled it
  2. Iatrogenic atrial septal defect: reassurance or inquisitiveness.Journal of interventional cardiac electrophysiology : an international journal of arrhythmias and pacing · 2018
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Malini MadhavanDivision of Cardiovascular Diseases, Department of Medicine, Mayo Clinic, Rochester, MN madhavan.malini@mayo.edu.
Xiaoxi YaoRobert D. and Patricia E. Kern Center for the Science of Health Care Delivery, Mayo Clinic, Rochester, MN Division of Health Care Policy and Research, Department of Health Services Research, Mayo Clinic, Rochester, MN.
Lindsey R SangaralinghamRobert D. and Patricia E. Kern Center for the Science of Health Care Delivery, Mayo Clinic, Rochester, MN Optum Labs, Cambridge, MA.
Samuel J AsirvathamDivision of Cardiovascular Diseases, Department of Medicine, Mayo Clinic, Rochester, MN.
Paul A FriedmanDivision of Cardiovascular Diseases, Department of Medicine, Mayo Clinic, Rochester, MN.
Christopher J McLeodDivision of Cardiovascular Diseases, Department of Medicine, Mayo Clinic, Rochester, MN.
Alan M SugrueDepartment of Medicine, Mayo Clinic, Rochester, MN.
Christopher V DeSimoneDivision of Cardiovascular Diseases, Department of Medicine, Mayo Clinic, Rochester, MN.
Peter A NoseworthyDivision of Cardiovascular Diseases, Department of Medicine, Mayo Clinic, Rochester, MN Robert D. and Patricia E. Kern Center for the Science of Health Care Delivery, Mayo Clinic, Rochester, MN.
Mayo Clinic in Arizona · USOptum (United States) · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundIncidental mobile thrombi are commonly found on endovascular leads of cardiac implantable electronic devices (CIEDs). Transseptal puncture for catheter ablation of arrhythmia poses a risk for paradoxical embolism. We examined risk of ischemic stroke, transient ischemic attack (TIA), or systemic embolism after transseptal ablation in patients with and without CIEDs. METHODS AND

resultsUsing a national administrative claims database, 31 720 patients who underwent a transseptal catheter ablation between January 2004 and September 2014 were identified. Two propensity-matched cohorts were created by matching demographic variables, administrative variables, Charlson Comorbidity Index, CHA2DS2-Vasc score, and year and indication for ablation (5533 and 11 300 patients with and without CIEDs). Incidence rates and Cox proportional hazards models were used to estimate risk of ischemic stroke, TIA, or systemic embolism for patients with and without CIEDs. Impact of oral anticoagulation (OAC) use on the endpoint was examined. Over a mean follow-up of 2.1 years, the incidence of the combined endpoint was 1.9 per 100 person-years in patients with CIEDs and 1.5 per 100 person-years in patients without CIEDs (P=0.03). Among patients not on OAC, presence of a cardiac device was associated with an increased risk (hazard ratio [HR], 1.71 [1.24-2.35]; P<0.01), whereas there was no association noted among patients treated with OAC (HR, 0.98 [0.75-1.28]).

conclusionCIEDs are associated with an increased risk of stroke, TIA, or systemic embolism after transseptal ablation, but this risk is attenuated with postablation OAC use. Role of anticoagulation post-transseptal ablation in patients with CIED warrants further investigation.

Indexed as

AgedArrhythmias, CardiacCatheter AblationDefibrillators, ImplantableFemaleHeart SeptumHumansIschemic Attack, TransientMaleMiddle AgedProportional Hazards ModelsRetrospective StudiesRisk FactorsStrokeThromboembolismatrial fibrillationcardiac ablationstrokesystemic embolismtransseptal puncture

Identifiers

PMID27076562
PMCPMC4843539
OpenAlexW2336750950

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.