Evidence map›Paper›PMID 27074891›Full record

ArticleBiomedical engineering online2016

A robust statistics driven volume-scalable active contour for segmenting anatomical structures in volumetric medical images with complex conditions.

Kuanquan Wang, Chao Ma

Abstract read
In one paragraph

Article in Biomedical engineering online, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Kuanquan WangSchool of Computer Science and Technology, Biocomputing Research Center, Harbin Institute of Technology, Harbin, China. wangkq@hit.edu.cn.
Chao MaSchool of Computer Science and Technology, Biocomputing Research Center, Harbin Institute of Technology, Harbin, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundAccurate segmentation of anatomical structures in medical images is a critical step in the development of computer assisted intervention systems. However, complex image conditions, such as intensity inhomogeneity, noise and weak object boundary, often cause considerable difficulties in medical image segmentation. To cope with these difficulties, we propose a novel robust statistics driven volume-scalable active contour framework, to extract desired object boundary from magnetic resonance (MR) and computed tomography (CT) imagery in 3D.

methodsWe define an energy functional in terms of the initial seeded labels and two fitting functions that are derived from object local robust statistics features. This energy is then incorporated into a level set scheme which drives the active contour evolving and converging at the desired position of the object boundary. Due to the local robust statistics and the volume scaling function in the energy fitting term, the object features in local volumes are learned adaptively to guide the motion of the contours, which thereby guarantees the capability of our method to cope with intensity inhomogeneity, noise and weak boundary. In addition, the initialization of active contour is simplified by select several seeds in the object and/or background to eliminate the sensitivity to initialization.

resultsThe proposed method was applied to extensive public available volumetric medical images with challenging image conditions. The segmentation results of various anatomical structures, such as white matter (WM), atrium, caudate nucleus and brain tumor, were evaluated quantitatively by comparing with the corresponding ground truths. It was found that the proposed method achieves consistent and coherent segmentation accuracy of 0.9246 ± 0.0068 for WM, 0.9043 ± 0.0131 for liver tumors, 0.8725 ± 0.0374 for caudate nucleus, 0.8802 ± 0.0595 for brain tumors, etc., measured by Dice similarity coefficients value for the overlap between the algorithm one and the ground truth. Further comparative experimental results showed desirable performances of the proposed method over several well-known segmentation methods in terms of accuracy and robustness.

conclusionWe proposed an approach to accurate segment volumetric medical images with complex conditions. The accuracy of segmentation, robustness to noise and contour initialization were validated on the basis of extensive MR and CT volumes.

Indexed as

AnatomyMagnetic Resonance ImagingTomography, X-Ray ComputedHumansImaging, Three-DimensionalMachine LearningModels, StatisticalStatistics as TopicActive contourComplex conditionsRobust statisticsVolume scalableVolumetric medical image segmentation

Identifiers

PMID27074891
PMCPMC4831199

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.