ArticleJournal of applied clinical medical physics2016
Quantitative outcome of registration methods for correcting cardiac drift in cardiac PET/CT imaging.
Article in Journal of applied clinical medical physics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed.
- Synergistic motion compensation strategies for positron emission tomography when acquired simultaneously with magnetic resonance imaging.Philosophical transactions. Series A, Mathematical, physical, and engineering sciences · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Myocardial perfusion studies suffer from artifacts caused by misalignment of the transmission and emission data due to the influences of voluntary and involuntary patient motion. Regardless of 68Ge or respiratory-averaged CT based attenuation correction and good patient cooperation, approximately 21% of perfusion studies exhibit artifacts arising from misalignment that cannot be corrected by manipulating the attenuation acquisition protocol. This misalignment, termed cardiac drift, is caused by slow-moving abdominal cavity contents that reposition the heart in the thorax and appear as myocardial uptake overlying the left CT lung in fused PET/CT images. This study evaluates three postimaging registration techniques to correct PET/CT misalignment by altering the transmission map to match myo-cardial uptake. Simulated misalignment studies were performed with a cardiac torso phantom filled with [18F]FDG at 10:1 myocardium/background. An air-filled saline bag affixed to the medial left lung surface served as a distensible lung. An initial CT acquisition was followed by successive PET acquisitions consisting of small displacements of the cardiac insert into the left lung. Phantom transmission scans were aligned to the myocardial uptake in the emission scans by applying 1) full rigid-body translations and rotations, 2) rigid-body restricted to medial / lateral and superior / inferior translation, or 3) an emission-driven method that adds myocardial tissue to the transmission scan. These methods were also applied to 10 low-likelihood coronary artery disease (CAD) patients showing signs of cardiac drift. Full rigid-body registration showed significant over-correction (p < 0.004) of activity concentrations in the artifact areas of the phantom data due the relocation of highly attenuating structures (i.e., spine). Inaccurate regional activity distributions were also observed as streaks extending from the spine and these results were replicated in the patient population. There was no significant difference between the true phantom activity concentration after correction with the emission-driven method. Misalignment corrected with the rigid-body registration results in an increase in activity concentration but fails to accurately recover the true concentration. These data suggest that a nonlinear image registration approach such as an emission-driven method results in a more uniform activity distribution throughout the myocardium, and is more appropriate for addressing the cardiac drift misalignment problem.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.