ReviewJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology2016
Traditional gamma cameras are preferred.
Review in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 18 citations in OpenAlex.
- Elimination of artifacts caused by residual radiopharmaceutical activity in injection site in myocardial perfusion imaging on Discovery NM 530c semiconductor gamma camera.EJNMMI research · 2025Article
- Capabilities of Modern Semiconductor Gamma Cameras in Radionuclide Diagnosis of Coronary Artery Disease.Diagnostics (Basel, Switzerland) · 2021Review
- Inter- and Intraobserver Repeatability of Myocardial Flow Reserve Values Determined with SPECT Study Using a Discovery NM530c Camera and Corridor 4DM Software.Journal of personalized medicine · 2021Article
- Mask-Related Motion Artifact on 99mTc-MIBI SPECT: Unexpected Pitfalls of SARS-CoV-2 Countermeasures.Diagnostics (Basel, Switzerland) · 2021Article
- Dedicated cardiac CZT SPECT is steadily moving to achieve its destiny.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2019Article
- A further step towards getting cardiac respiratory motion under control.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018Article
- Triage of patients for attenuation-corrected stress-first Tc-99m SPECT MPI using a simplified clinical pre-test scoring model.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018Article
- Impact of data-driven cardiac respiratory motion correction on the extent and severity of myocardial perfusion defects with free-breathing CZT SPECT.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2018Article
- The role of pharmacological stress testing in women.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016Review
- Recent Advances in Nuclear Cardiology.Nuclear medicine and molecular imaging · 2016Review
- Which SPECT for today, which SPECT for tomorrow?Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2016Article
- Myocardial perfusion scintigraphy dosimetry: optimal use of SPECT and SPECT/CT technologies in stress-first imaging protocol.Clinical and translational imaging · 2016Review
Corrections and comments
- Commented on by
Authors and funding
1 author at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Although the new solid-state dedicated cardiac cameras provide excellent spatial and energy resolution and allow for markedly reduced SPECT acquisition times and/or injected radiopharmaceutical activity, they have some distinct disadvantages compared to traditional sodium iodide SPECT cameras. They are expensive. Attenuation correction is not available. Cardio-focused collimation, advantageous to increase depth-dependent resolution and myocardial count density, accentuates diaphragmatic attenuation and scatter from subdiaphragmatic structures. Although supplemental prone imaging is therefore routinely advised, many patients cannot tolerate it. Moreover, very large patients cannot be accommodated in the solid-state camera gantries. Since data are acquired simultaneously with an arc of solid-state detectors around the chest, no temporally dependent "rotating" projection images are obtained. Therefore, patient motion can be neither detected nor corrected. In contrast, traditional sodium iodide SPECT cameras provide rotating projection images to allow technologists and physicians to detect and correct patient motion and to accurately detect the position of soft tissue attenuators and to anticipate associated artifacts. Very large patients are easily accommodated. Low-dose x-ray attenuation correction is widely available. Also, relatively inexpensive low-count density software is provided by many vendors, allowing shorter SPECT acquisition times and reduced injected activity approaching that achievable with solid-state cameras.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials