ArticleFrontiers in bioengineering and biotechnology2016
Voluntary-Driven Elbow Orthosis with Speed-Controlled Tremor Suppression.
Article in Frontiers in bioengineering and biotechnology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 2 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 2 syntheses or guidelines pooled it, 50 citations in OpenAlex.
- Need for mechanically and ergonomically enhanced tremor-suppression orthoses for the upper limb: a systematic review.Journal of neuroengineering and rehabilitation · 2019Pooled it
- Tremor Control Devices for Essential Tremor: A Systematic Literature Review.Tremor and other hyperkinetic movements (New York, N.Y.) · 2019Pooled it
- Designs of Upper Limb Tremor Suppression Orthoses: Efficacy and Wearer's Comfort.Journal of medical devices · 2025Review
- Learning to suppress tremors: a deep reinforcement learning-enabled soft exoskeleton for Parkinson's patients.Frontiers in robotics and AI · 2025Article
- Viscous damping of tremor using a wearable robot with an optimized mechanical metamaterial.Wearable technologies · 2024Article
- Diagnosis and Treatment of Tremor in Parkinson's Disease Using Mechanical Devices.Life (Basel, Switzerland) · 2022Review
- Mechatronic Design of a Prototype Orthosis to Support Elbow Joint Rehabilitation.Bioengineering (Basel, Switzerland) · 2022Article
- Review
- Optimal Trajectory Planning of the Variable-Stiffness Flexible Manipulator Based on CADE Algorithm for Vibration Reduction Control.Frontiers in bioengineering and biotechnology · 2021Article
- A Review on Wearable Technologies for Tremor Suppression.Frontiers in neurology · 2021Review
- 3D Scanning of the Forearm for Orthosis and HMI Applications.Frontiers in robotics and AI · 2021Article
- Controlling a motorized orthosis to follow elbow volitional movement: tests with individuals with pathological tremor.Journal of neuroengineering and rehabilitation · 2019Article
- Design of a noninvasive and smart hand tremor attenuation system with active control: a simulation study.Medical & biological engineering & computing · 2018Article
- Vib-bracelet: a passive absorber for attenuating forearm tremor.Medical & biological engineering & computing · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Robotic technology is gradually becoming commonplace in the medical sector and in the service of patients. Medical conditions that have benefited from significant technological development include stroke, for which rehabilitation with robotic devices is administered, and surgery assisted by robots. Robotic devices have also been proposed for assistance of movement disorders. Pathological tremor, among the most common movement disorders, is one such example. In practice, the dissemination and availability of tremor suppression robotic systems has been limited. Devices in the marketplace tend to either be non-ambulatory or to target specific functions, such as eating and drinking. We have developed a one degree-of-freedom (DOF) elbow orthosis that could be worn by an individual with tremor. A speed-controlled, voluntary-driven suppression approach is implemented with the orthosis. Typically tremor suppression methods estimate the tremor component of the signal and produce a canceling counterpart signal. The suggested approach instead estimates the voluntary component of the motion. A controller then actuates the orthosis based on the voluntary signal, while simultaneously rejecting the tremorous motion. In this work, we tested the suppressive orthosis using a one DOF robotic system that simulates the human arm. The suggested suppression approach does not require a model of the human arm. Moreover, the human input along with the orthosis forearm gravitational forces, of non-linear nature, are considered as part of the disturbance to the suppression system. Therefore, the suppression system can be modeled linearly. Nevertheless, the orthosis forearm gravitational forces can be compensated by the suppression system. The electromechanical design of the orthosis is presented, and data from an essential tremor patient is used as the human input. Velocity tracking results demonstrate an RMS error of 0.31 rad/s, and a power spectral density shows a reduction of the tremor signal by 99.8%, while the intentional component power was reduced by <1%.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.