ArticleSpringerPlus2016
Respiratory mechanics measured by forced oscillation technique in rheumatoid arthritis-related pulmonary abnormalities: frequency-dependence, heterogeneity and effects of smoking.
Article in SpringerPlus, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
11 citing papers in PubMed, 1 synthesis or guideline pooled it.
- A causal relationship between rheumatoid arthritis and bronchiectasis? A systematic review and meta-analysis.Chronic respiratory diseasePooled it
- Acute Effect of Submaximal Exercise on Respiratory System Impedance in Healthy Adults.Journal of functional morphology and kinesiology · 2025Article
- Forced oscillation technique in progressive pulmonary fibrosis in a single-center retrospective study.Scientific reports · 2025Article
- Bronchiolar disorders in systemic autoimmune rheumatic diseases.European respiratory review : an official journal of the European Respiratory Society · 2025Review
- Application of impulse oscillometry to detect interstitial lung disease and airway disease in adults with rheumatoid arthritis.BMC pulmonary medicine · 2023Observational
- Peripheral Blood Biomarkers for Rheumatoid Arthritis-Associated Interstitial Lung Disease: A Systematic Review.ACR open rheumatology · 2023Article
- Clinical significance and applications of oscillometry.European respiratory review : an official journal of the European Respiratory Society · 2022Review
- Lung cancer dynamics using fractional order impedance modeling on a mimicked lung tumor setup.Journal of advanced research · 2021Article
- Machine learning associated with respiratory oscillometry: a computer-aided diagnosis system for the detection of respiratory abnormalities in systemic sclerosis.Biomedical engineering online · 2021Article
- Complex obstructive lung disease - A diagnostic and management conundrum.Respiratory medicine case reports · 2020Article
- Comparison of impedance measured by the forced oscillation technique and pulmonary functions, including static lung compliance, in obstructive and interstitial lung disease.International journal of chronic obstructive pulmonary disease · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Rheumatoid arthritis (RA)-related pulmonary disorders specifically airway abnormalities and interstitial pneumonia (IP) are important extra-articular manifestations. The forced oscillation technique (FOT) is a useful method to assess respiratory impedance, respiratory resistance (Rrs) and reactance (Xrs), at different oscillatory frequencies during tidal breathing. The aim of this study was to characterize the respiratory mechanics of patients with RA and to relate them to parameters of the pulmonary function test and findings of chest CT images. Respiratory impedance of RA patients (n = 69) was measured as a function of frequency from 4 to 36 Hz using the FOT device and compared with that of healthy subjects (n = 10). Data were retrospectively reviewed. Patients were female-dominant (60.9 %) and 95.7 % had abnormal CT findings including airway and parenchymal abnormalities. Thirty-seven of 69 patients (53.6 %) were smokers. Rrs was significantly frequency-dependent in RA patients but not in the healthy subjects. Xrs were significantly frequency-dependent in both RA and healthy groups. Rrs was significantly higher during an expiratory phase in both RA and healthy groups. Xrs was significantly lower (more negative) during an expiratory phase than that during an inspiratory phase in RA patients but not in healthy subjects. Xrs of the RA group was significantly more negative than that of the normal control. There was no difference in impedance parameters between the airway lesion dominant (n = 27) and IP dominant groups (n = 23) in the RA group. The impedance parameters of the RA group significantly correlated with most parameters of the pulmonary function test. In pulmonary function test results, % of the predicted value for forced expiratory flow from 25 to 75 % of forced vital capacity was significantly lower and % of the predicted value for diffusing capacity of the lung for carbon monoxide was higher in the airway lesion dominant group than those in the IP dominant group. Krebs von den Lungen-6, a serum indicator of IP, was significantly higher in the IP group than that in the airway lesion dominant group. Taken together, the impedance results reflect abnormalities in pulmonary functions and structures in patients with RA.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.