Trial reportSurgical endoscopy2016
3D straight-stick laparoscopy versus 3D robotics for task performance in novice surgeons: a randomised crossover trial.
Trial report in Surgical endoscopy, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT02841657 (3D vs 2D Colorectal Resections and Valuation of Visual Load of Surgeons), which is not on this map. Cited by 6 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
3D vs 2D Colorectal Resections and Valuation of Visual Load of Surgeons
Who cites it
6 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.
- Transfer of skills between laparoscopic and robot-assisted surgery: a systematic review.Surgical endoscopy · 2023Pooled it
- Adoption and implementation of robotic colorectal surgery using structured training approach: an experience from tertiary referral center.Updates in surgery · 2025Article
- Robotic-assisted laparoscopic colpectomy combined with a hysterectomy and bilateral salpingo-oophorectomy versus a vaginal colpectomy in trans masculine individuals.International journal of transgender health · 2024Article
- Robotic Surgery in Pediatric Oncology: Lessons Learned from the First 100 Tumors-A Nationwide Experience.Annals of surgical oncology · 2022Article
- Learning curve of surgical novices using the single-port platform SymphonX: minimizing OR trauma to only one 15-mm incision.Surgical endoscopy · 2021Article
- [3 D laparoscopy versus 2 D laparoscopy : An up to date evaluation].Der Chirurg; Zeitschrift fur alle Gebiete der operativen Medizen · 2018Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
3 authors at 2 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundThe advent of three-dimensional passive stereoscopic imaging has led to the development of 3D laparoscopy. In simulation tasks, a reduction in error rate and performance time is seen with 3D compared to two-dimensional (2D) laparoscopy with both novice and expert surgeons. Robotics utilises 3D and instrument articulation through a console interface. Robotic trials have demonstrated that tasks performed in 3D produced fewer errors and quicker performance times compared with those in 2D. It was therefore perceived that the main advantage of robotic surgery was in fact 3D. Our aim was to compare 3D straight-stick laparoscopic task performance (3D) with robotic 3D (Robot), to determine whether robotic surgery confers additional benefit over and above 3D visualisation.
methodsWe randomised 20 novice surgeons to perform four validated surgical tasks, either with straight-stick 3D laparoscopy followed by 3D robotic surgery or in the reverse order. The trial was conducted in two fully functional operating theatres. The primary outcome of the study was the error rate as defined for each task, and the secondary outcome was the time taken to complete each task. The participants were asked to perform the tasks as quickly and as accurately as possible. Data were analysed using SPSS version 21.
resultsThe median error rate for completion of all four tasks with the robot was 2.75 and 5.25 for 3D with a P value <0.001. The median performance time for completion of all four tasks with the robot was 157.1 and 342.5 s for 3D with a P value <0.001.
conclusionsOur study has shown that for novice surgeons, there is a significant benefit in a simulated setting of 3D robotic systems over 3D straight-stick laparoscopy, in terms of reduced error rate and quicker task performance time.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.