Evidence map›Paper›PMID 27053826›Full record

ArticleProceedings of SPIE--the International Society for Optical Engineering2016

Deformable medical image registration of pleural cavity for photodynamic therapy by using finite-element based method.

Rozhin Penjweini, Michele M Kim, Andrea Dimofte, Jarod C Finlay, Timothy C Zhu

Abstract read
In one paragraph

Article in Proceedings of SPIE--the International Society for Optical Engineering, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Rozhin PenjweiniDepartment of Radiation Oncology, School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.
Michele M KimDepartment of Radiation Oncology, School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA; Department of Physics and Astronomy, University of Pennsylvania, Philadelphia, PA 19104, USA.
Andrea DimofteDepartment of Radiation Oncology, School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.
Jarod C FinlayDepartment of Radiation Oncology, School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.
Timothy C ZhuDepartment of Radiation Oncology, School of Medicine, University of Pennsylvania, Philadelphia, PA 19104, USA.

Funding

TUMOR HYPOXIA, PHOTOSENSITIZER, VASCULARITY AND PDTP01CA087971 · NCI · UNIVERSITY OF PENNSYLVANIA · PI BUSCH, THERESA M, CENGEL, KEITH A · 2001 to 2019
$24.8M
Image-guided treatment planning for pleural Photodynamic TherapyR01CA154562 · NCI · UNIVERSITY OF PENNSYLVANIA · PI ZHU, TIMOTHY C. · 2012 to 2016
$1.6M
NCI NIH HHS P01 CA087971NCI NIH HHS R01 CA154562
6 · The paper itself

Abstract

When the pleural cavity is opened during the surgery portion of pleural photodynamic therapy (PDT) of malignant mesothelioma, the pleural volume will deform. This impacts the delivered dose when using highly conformal treatment techniques. To track the anatomical changes and contour the lung and chest cavity, an infrared camera-based navigation system (NDI) is used during PDT. In the same patient, a series of computed tomography (CT) scans of the lungs are also acquired before the surgery. The reconstructed three-dimensional contours from both NDI and CTs are imported into COMSOL Multiphysics software, where a finite element-based (FEM) deformable image registration is obtained. The CT contour is registered to the corresponding NDI contour by overlapping the center of masses and aligning their orientations. The NDI contour is considered as the reference contour, and the CT contour is used as the target one, which will be deformed. Deformed Geometry model is applied in COMSOL to obtain a deformed target contour. The distortion of the volume at X, Y and Z is mapped to illustrate the transformation of the target contour. The initial assessment shows that FEM-based image deformable registration can fuse images acquired by different modalities. It provides insights into the deformation of anatomical structures along X, Y and Z-axes. The deformed contour has good matches to the reference contour after the dynamic matching process. The resulting three-dimensional deformation map can be used to obtain the locations of other critical anatomic structures, e.g., heart, during surgery.

Indexed as

CTfinite element-based methodimage deformable registrationlung and chest cavitymesotheliomaNDIPDT

Identifiers

PMID27053826
PMCPMC4819259

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.