Evidence map›Paper›PMID 27052546›Full record

ArticleGeneral thoracic and cardiovascular surgery2016

Comparison of saddle-shape flexibility and elliptical-shape stability between Cosgrove-Edwards and Memo-3D annuloplasty rings using three-dimensional analysis software.

Akira Tsuneto, Kiyoyuki Eishi, Takashi Miura, Kazuyoshi Tanigawa, Seiji Matsukuma, Takako Minami, Yuji Koide, Satoshi Ikeda, Hiroaki Kawano, Koji Maemura

Abstract readComparative StudyEvaluation Study
PubMed Publisher
In one paragraph

Article in General thoracic and cardiovascular surgery, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. 3D echocardiography in mitral valve prolapse.Frontiers in cardiovascular medicine · 2022
    Review
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Akira TsunetoDepartment of Cardiovascular Medicine, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan. atsuneto@nagasaki-u.ac.jp.
Kiyoyuki EishiDepartment of Cardiovascular Surgery, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
Takashi MiuraDepartment of Cardiovascular Surgery, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
Kazuyoshi TanigawaDepartment of Cardiovascular Surgery, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
Seiji MatsukumaDepartment of Cardiovascular Surgery, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
Takako MinamiDepartment of Cardiovascular Medicine, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
Yuji KoideDepartment of Cardiovascular Medicine, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
Satoshi IkedaDepartment of Cardiovascular Medicine, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
Hiroaki KawanoDepartment of Cardiovascular Medicine, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.
Koji MaemuraDepartment of Cardiovascular Medicine, Nagasaki University Hospital, 1-7-1 Sakamoto, Nagasaki, 852-8501, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo compare three-dimensional dynamics between implanted Cosgrove-Edwards and Sorin Memo-3D annuloplasty rings during the cardiac cycle.

methodsWe examined 11 Cosgrove-Edwards rings and 20 Sorin Memo-3D rings after mitral plasty using real-time three-dimensional transesophageal echocardiography. We evaluated ring height, ellipticity, and geometry during one cardiac cycle. Four evenly spaced phases each selected during systole and diastole were assessed using REAL VIEW software.

resultsThe height of the Cosgrove-Edwards and Sorin Memo-3D rings was similar (2.3 ± 0.8 vs. 1.9 ± 0.9 mm, p = 0.44). The maximum difference in ring height during one cardiac cycle (change in height) was larger for the Cosgrove-Edwards than the Sorin Memo-3D rings (2.3 ± 0.8 vs. 1.5 ± 0.6 mm, p = 0.014). Ellipticity and the maximum difference in ellipticity during one cardiac cycle (change in ellipticity) were larger for Cosgrove-Edwards than Sorin Memo-3D rings (80.0 ± 9.1 vs. 72.0 ± 4.8 %, p = 0.014, respectively, and 12.0 ± 3.1 vs. 6.0 ± 1.8 %, p < 0.001).

conclusionsCosgrove-Edwards rings were more flexible, whereas Sorin Memo-3D rings maintained the elliptical shape more effectively.

Indexed as

SoftwareAgedDiastoleEchocardiography, TransesophagealEquipment DesignFemaleHumansMaleMitral Valve AnnuloplastyMitral Valve InsufficiencyMitral Valve ProlapseSurgical EquipmentSystoleCosgrove-Edwards annuloplasty ringMemo-3D annuloplasty ringMitral annular dynamicsMitral repairThree-dimensional trans-esophageal echocardiography

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.