How Much Is the Dose Varying between Follow-Up CT-Examinations Performed on the Same Scanner with the Same Imaging Protocol?

Saravanabavaan Suntharalingam, Franz Ferdinand Stecker, Nika Guberina, Adrian Ringelstein, Thomas Schlosser, Jens Matthias Theysohn, Michael Forsting, Kai Nassenstein

Abstract read
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Value of repeat CT for nonoperative management of patients with blunt liver and spleen injury: a systematic review.European journal of trauma and emergency surgery : official publication of the European Trauma Society · 2021
    Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
  6. Radiation Exposure in Computed Tomography.Deutsches Arzteblatt international · 2023
    Review
  7. Article
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Saravanabavaan SuntharalingamDepartment of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
Franz Ferdinand SteckerDepartment of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
Nika GuberinaDepartment of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
Adrian RingelsteinDepartment of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
Thomas SchlosserDepartment of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
Jens Matthias TheysohnDepartment of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
Michael ForstingDepartment of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.
Kai NassensteinDepartment of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeTo investigate the dose variation between follow-up CT examinations, when a patient is examined several times on the same scanner with the identical scan protocol which comprised automated exposure control. MATERIAL AND

methodsThis retrospective study was approved by the local ethics committee. The volume computed tomography dose index (CTDIvol) and the dose-length-product (DLP) were recorded for 60 cancer patients (29 male, 31 female, mean age 60.1 years), who received 3 follow-up CT examinations each composed of a non-enhanced scan of the liver (LI-CT) and a contrast-enhanced scan of chest (CH-CT) and abdomen (AB-CT). Each examination was performed on the same scanner (Siemens Definition FLASH) equipped with automated exposure control (CARE Dose 4D and CARE KV) using the identical scan protocol.

resultsThe median percentage difference in DLP between follow-up examinations was 9.6% for CH-CT, 10.3% for LI-CT, and 10.1% for AB-CT; the median percentage difference in CTDIvol 8.3% for CH-CT, 7.4% for LI-CT and 7.7% for AB-CT (p<0.0001 for all values). The maximum difference in DLP between follow-up examinations was 67.5% for CH-CT, 50.8% for LI-CT and 74.3% for AB-CT; the maximum difference in CTDIvol 62.9% for CH-CT, 47.2% for LI-CT, and 49% for AB-CT.

conclusionA significant variance in the radiation dose occurs between follow-up CT examinations when the same CT scanner and the identical imaging protocol are used in combination with automated exposure control.

Indexed as

Radiation DosageTomography, X-Ray ComputedFemaleFollow-Up StudiesHumansMaleMiddle Aged

Identifiers

PMID27050659
PMCPMC4822887

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.