Feasibility of assessing pulmonary blood volume using C-arm CT during transpulmonary chemoperfusion and chemoembolization in primary and secondary lung tumours.

Thomas J Vogl, Nour-Eldin A Nour-Eldin, Nagy N N Naguib, Thomas Lehnert, Hanns Ackermann, Renate Hammerstingl, Marcus Hezel

Open access · greenAbstract read
In one paragraph

Article in The British journal of radiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.8field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 2 countries.

Thomas J Vogl1 Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany.
Nour-Eldin A Nour-Eldin1 Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany.
Nagy N N Naguib1 Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany.
Thomas Lehnert1 Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany.
Hanns Ackermann4 Department of Biomedical Statistics, Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany.
Renate Hammerstingl1 Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany.
Marcus Hezel1 Institute for Diagnostic and Interventional Radiology, Johann Wolfgang Goethe University Frankfurt, Frankfurt, Germany.
Goethe University Frankfurt · DECairo University · EG

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveAssessment of parenchymal blood volume (PBV) of primary and secondary pulmonary malignancies by using a C-arm CT, regarding its role in detecting early functional response to transpulmonary chemoembolization (TPCE) and clinical practicability.

methods21 patients with a mean age of 56.77 years, who were assigned to TPCE during their palliative treatment, were included. PBV and the diameter of tumours were analyzed. PBV maps were calculated from three-dimensional CT-angiographic (3D-CTA) data sets. Imaging was performed on a flat detector, C-arm CT. Groups of response were classified according to the criteria of the response evaluation criteria in solid tumours. Statistically significant differences were determined and Pearson's regression analysis correlated PBV and diameter as parameters of response to treatment.

resultsDuring 4.91 sessions, median diameter increased 18.18% (p > 0.05) and PBV reduced 39.62% (p > 0.05). Functional and imaging response per tumour was statistical significantly different (p ≤ 0.05). Correlation coefficient was r = 0.058. 2/41 tumours showed partial response; 31/41 tumours showed stable disease; and 8/41 tumours showed progressive disease. The highest pre-treatment PBV values were measured in decreasing tumours (206.93 ml l(-1)), and the lowest values were measured in increasing tumours (60.17 ml l(-1); p > 0.05). The lowest values were also measured in lung cancer (53.02 ml l(-1)) that was significantly different to uterine leiomyosarcoma (103.31 ml l(-1)) and renal cell cancer (113.14 ml l(-1); p ≤ 0.05).

conclusionAssessment of PBV maps by using 3D-CTA image data is feasible in the clinical routine. PBV shows a stronger response to TPCE treatment than measurement in diameter and should be considered as a response parameter for early detection. ADVANCES IN KNOWLEDGE: Assessment of PBV using C-arm CT during TPCE is a feasible technique. Assessment of PBV might be useful in assessing response to treatment.

Indexed as

Blood VolumeAdultAgedChemoembolization, TherapeuticComputed Tomography AngiographyDrug MonitoringFeasibility StudiesFemaleHumansLung NeoplasmsMaleMiddle AgedNeovascularization, PathologicRadiography, InterventionalRetrospective StudiesTreatment Outcome

Identifiers

PMID27046514
PMCPMC5258138
OpenAlexW2331031921

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.