Evidence map›Paper›PMID 27043764›Full record

ArticleThe British journal of radiology2016

Tomosynthesis can facilitate accurate measurement of joint space width under the condition of the oblique incidence of X-rays in patients with rheumatoid arthritis.

Yohei Ono, Rina Kashihara, Nobutoshi Yasojima, Hideki Kasahara, Yuka Shimizu, Kenichi Tamura, Kaori Tsutsumi, Kenneth Sutherland, Takao Koike, Tamotsu Kamishima

Abstract read
In one paragraph

Article in The British journal of radiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors.

Yohei Ono1 Department of Radiology, NTT Sapporo Medical Center, Sapporo, Japan.
Rina Kashihara2 Department of Radiology, Department of Medical Technology, Sunagawa City Medical Center, Sunagawa, Japan.
Nobutoshi Yasojima3 Department of Radiology, NTT Sapporo Medical Center, Sapporo, Japan.
Hideki Kasahara4 Department of Rheumatology, NTT Sapporo Medical Center, Sapporo, Japan.
Yuka Shimizu5 Division of Rheumatology, Endocrinology and Nephrology, Hokkaido University Graduate School of Medicine, Sapporo, Japan.
Kenichi Tamura6 Department of Mechanical Engineering, College of Engineering, Nihon University, Koriyama, Japan.
Kaori Tsutsumi7 Faculty of Health Sciences, Hokkaido University, Sapporo, Japan.
Kenneth Sutherland8 Graduate School of Medicine, Hokkaido University, Sapporo, Japan.
Takao Koike4 Department of Rheumatology, NTT Sapporo Medical Center, Sapporo, Japan.
Tamotsu Kamishima7 Faculty of Health Sciences, Hokkaido University, Sapporo, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveAccurate evaluation of joint space width (JSW) is important in the assessment of rheumatoid arthritis (RA). In clinical radiography of bilateral hands, the oblique incidence of X-rays is unavoidable, which may cause perceptional or measurement error of JSW. The objective of this study was to examine whether tomosynthesis, a recently developed modality, can facilitate a more accurate evaluation of JSW than radiography under the condition of oblique incidence of X-rays.

methodsWe investigated quantitative errors derived from the oblique incidence of X-rays by imaging phantoms simulating various finger joint spaces using radiographs and tomosynthesis images. We then compared the qualitative results of the modified total Sharp score of a total of 320 joints from 20 patients with RA between these modalities.

resultsA quantitative error was prominent when the location of the phantom was shifted along the JSW direction. Modified total Sharp scores of tomosynthesis images were significantly higher than those of radiography, that is to say JSW was regarded as narrower in tomosynthesis than in radiography when finger joints were located where the oblique incidence of X-rays is expected in the JSW direction.

conclusionTomosynthesis can facilitate accurate evaluation of JSW in finger joints of patients with RA, even with oblique incidence of X-rays. ADVANCES IN KNOWLEDGE: Accurate evaluation of JSW is necessary for the management of patients with RA. Through phantom and clinical studies, we demonstrate that tomosynthesis may achieve more accurate evaluation of JSW.

Indexed as

AdultAgedAged, 80 and overArthritis, RheumatoidArthrographyFemaleFinger JointHumansMaleMiddle AgedPatient PositioningPhantoms, ImagingRadiographic Image EnhancementRadiographic Image Interpretation, Computer-AssistedReproducibility of ResultsSensitivity and Specificity

Identifiers

PMID27043764
PMCPMC5258159

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.