Evidence map›Paper›PMID 27043682›Full record

ArticleMedicine2016

First Case Report of Acute Renal Failure After Mesh-Plug Inguinal Hernia Repair in a Kidney Transplant Recipient.

Massimiliano Veroux, Vincenzo Ardita, Domenico Zerbo, Pietro Caglià, Stefano Palmucci, Nunziata Sinagra, Alessia Giaquinta, Pierfrancesco Veroux

Open access · goldAbstract readCase Reports
In one paragraph

Article in Medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.3field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 13 citations in OpenAlex.

  1. Article
  2. Review
  3. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 1 institution in 1 country.

Massimiliano VerouxFrom the Vascular Surgery and Organ Transplant Unit (MV, VA, DZ, PC, NS, AG, PV), Department of Medical and Surgical Sciences and Advanced Technologies; and Radiodiagnostic and Radiotherapy Unit (SP), University Hospital of Catania, Italy.
Vincenzo Ardita
Domenico Zerbo
Pietro Caglià
Stefano Palmucci
Nunziata Sinagra
Alessia Giaquinta
Pierfrancesco Veroux
University of Catania · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Acute renal failure due to ureter compression after a mesh-plug inguinal repair in a kidney transplant recipient has not been previously reported to our knowledge. A 62-year-old man, who successfully underwent kidney transplantation from a deceased donor 6 years earlier, was admitted for elective repair of a direct inguinal hernia. The patient underwent an open mesh-plug repair of the inguinal hernia with placement of a plug in the preperitoneal space. We did not observe the transplanted ureter and bladder during dissection of the inguinal canal. Immediately after surgery, the patient became anuric, and a graft sonography demonstrated massive hydronephrosis. The serum creatinine level increased rapidly, and the patient underwent an emergency reoperation 8 hours later. During surgery, we did not identify the ureter but, immediately after plug removal, urine output increased progressively. We completed the hernia repair using the standard technique, without plug interposition, and the postoperative course was uneventful with complete resolution of graft dysfunction 3 days later. Furthermore, we reviewed the clinical features of complications related to inguinal hernia surgery. An increased risk of urological complications was reported recently in patients with a previous prosthetic hernia repair undergoing kidney transplantation, mainly due to the mesh adhesion to surrounding structures, making the extraperitoneal dissection during the transplant surgery very challenging. Moreover, older male kidney transplant recipients undergoing an inguinal hernia repair may be at higher risk of graft dysfunction due to inguinal herniation of a transplanted ureter. Mesh-plug inguinal hernia repair is a safe surgical technique, but this unique case suggests that kidney transplant recipients with inguinal hernia may be at higher risk of serious urological complications. Surgeons must be aware of the graft and ureter position before proceeding with hernia repair. A prompt diagnosis with graft sonography and abdominal computed tomography scan and emergency surgery may avoid the need for nephrostomy and may resolve graft dysfunction more rapidly.

Indexed as

Acute Kidney InjuryHernia, InguinalHumansKidney Function TestsKidney TransplantationMalePostoperative ComplicationsReoperationSurgical Mesh

Identifiers

PMID27043682
PMCPMC4998543
OpenAlexW2465267214

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.