Feasibility of A-mode ultrasound attenuation as a monitoring method of local hyperthermia treatment.

Noraida Abd Manaf, Maizatul Nadwa Che Aziz, Dzulfadhli Saffuan Ridzuan, Maheza Irna Mohamad Salim, Asnida Abd Wahab, Khin Wee Lai, Yan Chai Hum

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.5field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 11 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Noraida Abd ManafFaculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia, 81310, Johor Baharu, Malaysia. noar22@yahoo.com.
Maizatul Nadwa Che AzizFaculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia, 81310, Johor Baharu, Malaysia.
Dzulfadhli Saffuan RidzuanFaculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia, 81310, Johor Baharu, Malaysia.
Maheza Irna Mohamad SalimFaculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia, 81310, Johor Baharu, Malaysia.
Asnida Abd WahabFaculty of Biosciences and Medical Engineering, Universiti Teknologi Malaysia, 81310, Johor Baharu, Malaysia.
Khin Wee LaiBiomedical Engineering Department, Faculty of Engineering, University of Malaya, 50603, Kuala Lumpur, Malaysia.
Yan Chai HumMIMOS Berhad, Taman Teknologi Malaysia, 57000, Kuala Lumpur, WP Kuala Lumpur, Malaysia.
University of Technology Malaysia · MYMIMOS (Malaysia) · MYUniversity of Malaya · MY

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Recently, there is an increasing interest in the use of local hyperthermia treatment for a variety of clinical applications. The desired therapeutic outcome in local hyperthermia treatment is achieved by raising the local temperature to surpass the tissue coagulation threshold, resulting in tissue necrosis. In oncology, local hyperthermia is used as an effective way to destroy cancerous tissues and is said to have the potential to replace conventional treatment regime like surgery, chemotherapy or radiotherapy. However, the inability to closely monitor temperature elevations from hyperthermia treatment in real time with high accuracy continues to limit its clinical applicability. Local hyperthermia treatment requires real-time monitoring system to observe the progression of the destroyed tissue during and after the treatment. Ultrasound is one of the modalities that have great potential for local hyperthermia monitoring, as it is non-ionizing, convenient and has relatively simple signal processing requirement compared to magnetic resonance imaging and computed tomography. In a two-dimensional ultrasound imaging system, changes in tissue microstructure during local hyperthermia treatment are observed in terms of pixel value analysis extracted from the ultrasound image itself. Although 2D ultrasound has shown to be the most widely used system for monitoring hyperthermia in ultrasound imaging family, 1D ultrasound on the other hand could offer a real-time monitoring and the method enables quantitative measurement to be conducted faster and with simpler measurement instrument. Therefore, this paper proposes a new local hyperthermia monitoring method that is based on one-dimensional ultrasound. Specifically, the study investigates the effect of ultrasound attenuation in normal and pathological breast tissue when the temperature in tissue is varied between 37 and 65 °C during local hyperthermia treatment. Besides that, the total protein content measurement was also conducted to investigate the relationship between attenuation and tissue denaturation level at different temperature ranges. The tissues were grouped according to their histology results, namely normal tissue with large predominance of cells (NPC), cancer tissue with large predominance of cells (CPC) and cancer with high collagen fiber content (CHF). The result shows that the attenuation coefficient of ultrasound measured following the local hyperthermia treatment increases with the increment of collagen fiber content in tissue as the CHF attenuated ultrasound at the highest rate, followed by NPC and CPC. Additionally, the attenuation increment is more pronounced at the temperature over 55 °C. This describes that the ultrasound wave experienced more energy loss when it propagates through a heated tissue as the tissue structure changes due to protein coagulation effect. Additionally, a significant increase in the sensitivity of attenuation to protein denaturation is also observed with the highest sensitivity obtained in monitoring NPC. Overall, it is concluded that one-dimensional ultrasound can be used as a monitoring method of local hyperthermia since its attenuation is very sensitive to the changes in tissue microstructure during hyperthermia.

Indexed as

Monitoring, PhysiologicUltrasonicsAnimalsFeasibility StudiesFemaleHyperthermia, InducedMammary Glands, AnimalMiceProtein DenaturationSignal Processing, Computer-AssistedTemperatureLocal hyperthermiaMonitoringOne-dimensional ultrasoundTotal protein

Identifiers

PMID27039402
OpenAlexW2318015217

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.