Evidence map›Paper›PMID 27039299›Full record

ArticleBMC medical research methodology2016

Validation and reliability of a guideline appraisal mini-checklist for daily practice use.

Andrea Siebenhofer, Thomas Semlitsch, Thomas Herborn, Ulrich Siering, Ina Kopp, Johannes Hartig

Abstract readComparative StudyValidation Study
In one paragraph

Article in BMC medical research methodology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Review
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Andrea SiebenhoferInstitute of General Practice and Evidence-Based Health Services Research, Medical University of Graz, Auenbruggerplatz 2/9, 8036, Graz, Austria. andrea.siebenhofer@medunigraz.at.
Thomas SemlitschInstitute of General Practice and Evidence-Based Health Services Research, Medical University of Graz, Auenbruggerplatz 2/9, 8036, Graz, Austria.
Thomas HerbornInstitute of General Practice, Goethe University Frankfurt, Frankfurt, Germany.
Ulrich SieringInstitute for Quality and Efficiency in Health Care (IQWiG), Cologne, Germany.
Ina KoppAssociation of Scientific Medical Societies' Institute of Medical Knowledge Management (AWMF-IMWi), Marburg, Germany.
Johannes HartigDepartment of Educational Quality and Evaluation, German Institute for International Educational Research (DIPF), Frankfurt, Germany.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe use of comprehensive instruments for guideline appraisal is time-consuming and requires highly qualified personnel. Since practicing physicians are generally busy, the rapid-assessment Mini-Checklist (MiChe) tool was developed to help them evaluate the quality and utility of guidelines quickly. The aim of this study was to validate the MiChe in comparison to the AGREE II instrument and to determine its reliability as a tool for guideline appraisal.

methodsTen guidelines that are relevant to general practice and had been evaluated by 2 independent reviewers using AGREE II were assessed by 12 GPs using the MiChe. The strength of the correlation between average MiChe ratings and AGREE II total scores was estimated using Pearson's correlation coefficient. Inter-rater reliability for MiChe overall quality ratings and endorsements was determined using intra-class correlations (ICC) and Kendall's W for ordinal recommendations. To determine the GPs' satisfaction with the MiChe, mean scores for the ratings on five questions were computed using a six-point Likert scale.

resultsThe study showed a high level of agreement between MiChe and AGREE II in the quality rating of guidelines (Pearson's r = 0.872; P < 0.001). Inter-rater-reliability for overall MiChe ratings (ICC = 0.755; P < 0.001) and endorsements (Kendall's W = 0.73; P < 0.001) were high. The mean time required for guideline assessment was less than 15 min und user satisfaction was generally high.

conclusionsThe MiChe performed well in comparison to AGREE II and is suitable for the rapid evaluation of guideline quality and utility in practice.

trial registrationGerman Clinical Trials Register: DRKS00007480.

Indexed as

AdultAgedChecklistFemaleGeneral PracticeGeneral PractitionersGermanyGuideline AdherenceHumansMaleMiddle AgedObserver VariationPractice Guidelines as TopicPractice Patterns, Physicians'Surveys and QuestionnairesAGREE II instrumentGeneral practitionersGuideline assessmentMini-checklistReliabilityValidation

Identifiers

PMID27039299
PMCPMC4818926

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked