Evidence map›Paper›PMID 27037687›Full record

ArticleJournal of medical systems2016

A Multi-Constraint Scheme with Authorized Mechanism for the Patient Safety.

Jen-Ming Hsu, Yao-Chang Yu, Ting-Wei Hou, Wei-Guang Teng, Tzu-Chiang Chiang, Ming-Chang Yang

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical systems, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Jen-Ming HsuDepartment of Engineering Science, National Cheng Kung University, Tainan, 701, Taiwan. n98991069@mail.ncku.edu.tw.
Yao-Chang YuTechknowledge Services Group Inc., Tainan, Taiwan. yuy0329@hotmail.com.
Ting-Wei HouDepartment of Engineering Science, National Cheng Kung University, Tainan, 701, Taiwan.
Wei-Guang TengDepartment of Engineering Science, National Cheng Kung University, Tainan, 701, Taiwan.
Tzu-Chiang ChiangDepartment of Information Management, Tunghai University, Taichung, 407, Taiwan.
Ming-Chang YangDepartment of Medical Information, Kaohsiung Medical University Hospital, Kaohsiung Medical University, Kaohsiung, 807, Taiwan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Many research works have attempted to introduce passive RFID technology into medical systems to reduce medical errors. However, most of these proposed works focused on identifying patients and objects. If an RFID based medical system is only good for identifying patients and medical objects but not capable of halting any medical process immediately, then it is not possible to prevent medical errors from happening. Our research focuses on a mechanism to detect and to avoid medical harm before it occurs to patients. In this paper, we propose to incorporate multiple-constraints into the authorization scheme and used this scheme as a basis for implementing a medical management system avoiding medical errors to assist medical staff. Specifically, our scheme ensures that a medical operation is if and only if enabled when the constraints are being satisfied that an "identified patient" is being treated by a "certified medical staff member" within an "authorized area". In practical environments, our authorization scheme can be applied to various healthcare applications, and we develop a prototype system and test it in three applications: X-ray control, specimen collection, and blood transfusion management. The experimental results show that the system can be used to enable X-ray when the X-ray is in authorized location and operated by authorized operator. For the specimen collection and blood transfusion, the logs showing which medical staff has done specimen or blood transfusion on which patient at authorized location are correctly recorded into Hospital Information System (HIS). The locating process can be performed within 10 to 20 seconds, and the locating error is less than 2 meters.

Indexed as

Patient SafetyBlood TransfusionHospital Information SystemsHumansMedical ErrorsRadio Frequency Identification DeviceSafety ManagementSpecimen HandlingX-RaysAuthorizationHealthcareMedical information systemPatient safetyRFID

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.