A model-based scatter artifacts correction for cone beam CT.

Wei Zhao, Don Vernekohl, Jun Zhu, Luyao Wang, Lei Xing

Abstract read
In one paragraph

Article in Medical physics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 24 papers.

0numbers the graph read from it
0cells of the map it votes in
24citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

24 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Review
  7. Article
  8. Article
  9. Review
  10. Article
  11. Adaptive proton therapy.Physics in medicine and biology · 2021
    Review
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Dynamic fluence field modulation for miscentered patients in computed tomography.Journal of medical imaging (Bellingham, Wash.) · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Wei ZhaoDepartment of Biomedical Engineering, Huazhong University of Science and Technology, Hubei 430074, China.
Don VernekohlDepartment of Radiation Oncology, Stanford University, Stanford, California 94305.
Jun ZhuDepartment of Biomedical Engineering, Huazhong University of Science and Technology, Hubei 430074, China.
Luyao WangDepartment of Biomedical Engineering, Huazhong University of Science and Technology, Hubei 430074, China.
Lei XingDepartment of Radiation Oncology, Stanford University, Stanford, California 94305.

Funding

Computational Tools for Next Generation Volumetric Cone Beam Computed TomographyR01EB016777 · NIBIB · STANFORD UNIVERSITY · PI XING, LEI · 2013 to 2016
$2.1M
NIBIB NIH HHS 1R01-EB016777NIBIB NIH HHS R01 EB016777
6 · The paper itself

Abstract

purposeDue to the increased axial coverage of multislice computed tomography (CT) and the introduction of flat detectors, the size of x-ray illumination fields has grown dramatically, causing an increase in scatter radiation. For CT imaging, scatter is a significant issue that introduces shading artifact, streaks, as well as reduced contrast and Hounsfield Units (HU) accuracy. The purpose of this work is to provide a fast and accurate scatter artifacts correction algorithm for cone beam CT (CBCT) imaging.

methodsThe method starts with an estimation of coarse scatter profiles for a set of CBCT data in either image domain or projection domain. A denoising algorithm designed specifically for Poisson signals is then applied to derive the final scatter distribution. Qualitative and quantitative evaluations using thorax and abdomen phantoms with Monte Carlo (MC) simulations, experimental Catphan phantom data, and in vivo human data acquired for a clinical image guided radiation therapy were performed. Scatter correction in both projection domain and image domain was conducted and the influences of segmentation method, mismatched attenuation coefficients, and spectrum model as well as parameter selection were also investigated.

resultsResults show that the proposed algorithm can significantly reduce scatter artifacts and recover the correct HU in either projection domain or image domain. For the MC thorax phantom study, four-components segmentation yields the best results, while the results of three-components segmentation are still acceptable. The parameters (iteration number K and weight β) affect the accuracy of the scatter correction and the results get improved as K and β increase. It was found that variations in attenuation coefficient accuracies only slightly impact the performance of the proposed processing. For the Catphan phantom data, the mean value over all pixels in the residual image is reduced from -21.8 to -0.2 HU and 0.7 HU for projection domain and image domain, respectively. The contrast of the in vivo human images is greatly improved after correction.

conclusionsThe software-based technique has a number of advantages, such as high computational efficiency and accuracy, and the capability of performing scatter correction without modifying the clinical workflow (i.e., no extra scan/measurement data are needed) or modifying the imaging hardware. When implemented practically, this should improve the accuracy of CBCT image quantitation and significantly impact CBCT-based interventional procedures and adaptive radiation therapy.

Indexed as

ArtifactsMonte Carlo MethodScattering, RadiationCone-Beam Computed TomographyHumansImage Processing, Computer-AssistedPelvisPhantoms, ImagingSignal-To-Noise Ratio

Identifiers

PMID27036571
PMCPMC4798999

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.