Evidence map›Paper›PMID 27036561›Full record

ArticleMedical physics2016

Comparison of three dimensional strain volume reconstructions using SOUPR and wobbler based acquisitions: A phantom study.

Wenjun Yang, Atul Ingle, Tomy Varghese

Open access · bronzeAbstract readComparative Study
In one paragraph

Article in Medical physics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.4field-weighted citation impact, top 19% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Sensorless End-to-End Freehand 3-D Ultrasound Reconstruction With Physics-Guided Deep Learning.IEEE transactions on ultrasonics, ferroelectrics, and frequency control · 2024
    Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Wenjun YangDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin 53705.
Atul IngleDepartment of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706.
Tomy VargheseDepartment of Medical Physics, University of Wisconsin School of Medicine and Public Health, University of Wisconsin-Madison, Madison, Wisconsin 53705 and Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706.
University of Wisconsin–Madison · US

Funding

Real-time Ultrasonic Monitoring of Tumor AblationR01CA112192 · NCI · UNIVERSITY OF WISCONSIN-MADISON · PI VARGHESE, TOMY · 2007 to 2017
$2.6M
NCI NIH HHS R01 CA112192NCI NIH HHS R01 CA112192-08
6 · The paper itself

Abstract

purposeUltrasound strain imaging is a relatively low cost and portable modality for monitoring percutaneous thermal ablation of liver neoplasms. However, a 3D strain volume reconstruction from existing 2D strain images is necessary to fully delineate the thermal dose distribution. Tissue mimicking (TM) phantom experiments were performed to validate a novel volume reconstruction algorithm referred to as sheaf of ultrasound planes reconstruction (SOUPR), based on a series of 2D rotational imaging planes.

methodsReconstruction using SOUPR was formulated as an optimization problem with constraints on data consistency with 2D strain images and data smoothness of the volume data. Reconstructed ablation inclusion dimensions, volume, and elastographic signal to noise ratio (SNRe) and contrast to noise ratio (CNRe) were compared with conventional 3D ultrasound strain imaging based on interpolating a series of quasiparallel 2D strain images with a wobbler transducer.

resultsVolume estimates of the phantom inclusion were in a similar range for both acquisition approaches. SNRe and CNRe obtained with SOUPR were significantly higher on the order of 250% and 166%, respectively. The mean error of the inclusion dimension reconstructed with a wobbler transducer was on the order of 10.4%, 3.5%, and 19.0% along the X, Y, and Z axes, respectively, while the error with SOUPR was on the order of 2.6%, 2.8%, and 9.6%. A qualitative comparison of SOUPR and wobbler reconstruction was also performed using a thermally ablated region created in ex vivo bovine liver tissue.

conclusionsThe authors have demonstrated using experimental evaluations with a TM phantom that the reconstruction results obtained with SOUPR were superior when compared with a conventional wobbler transducer in terms of inclusion shape preservation and detectability.

Indexed as

Phantoms, ImagingStress, MechanicalTransducersAlgorithmsAnimalsCattleElasticity Imaging TechniquesImaging, Three-DimensionalLiverSignal-To-Noise Ratio

Identifiers

PMID27036561
PMCPMC4788604
OpenAlexW2294827710

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.