Improving the Sensitivity, Resolution, and Peak Capacity of Gradient Elution in Capillary Liquid Chromatography with Large-Volume Injections by Using Temperature-Assisted On-Column Solute Focusing.

Rachael E Wilson, Stephen R Groskreutz, Stephen G Weber

Open access · greenAbstract read
In one paragraph

Article in Analytical chemistry, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
3.9field-weighted citation impact, top 7% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 34 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. [Research advances in nano liquid chromatography instrumentation].Se pu = Chinese journal of chromatography · 2021
    Review
  6. Review
  7. Article
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Rachael E WilsonDepartment of Chemistry, University of Pittsburgh , Pittsburgh, Pennsylvania 15260, United States.
Stephen R GroskreutzDepartment of Chemistry, University of Pittsburgh , Pittsburgh, Pennsylvania 15260, United States.
Stephen G WeberDepartment of Chemistry, University of Pittsburgh , Pittsburgh, Pennsylvania 15260, United States.
University of Pittsburgh · US

Funding

SENSITIVE AND SELECTIVE DETECTION OF PEPTIDESR01GM044842 · NIGMS · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI WEBER, STEPHEN G. · 1991 to 2018
$4.9M
Fast Online Microdialysis/Liquid Chromatography for Monoamine NeurotransmittersR01MH104386 · NIMH · UNIVERSITY OF PITTSBURGH AT PITTSBURGH · PI WEBER, STEPHEN G. · 2014 to 2017
$1.3M
NIGMS NIH HHS R01 GM044842NIMH NIH HHS R01 MH104386
6 · The paper itself

Abstract

Capillary HPLC (cLC) with gradient elution is the separation method of choice for the fields of proteomics and metabolomics. This is due to the complementary nature of cLC flow rates and electrospray or nanospray ionization mass spectrometry (ESI-MS). The small column diameters result in good mass sensitivity. Good concentration sensitivity is also possible by injection of relatively large volumes of solution and relying on solvent-based solute focusing. However, if the injection volume is too large or solutes are poorly retained during injection, volume overload occurs which leads to altered peak shapes, decreased sensitivity, and lower peak capacity. Solutes that elute early even with the use of a solvent gradient are especially vulnerable to this problem. In this paper, we describe a simple, automated instrumental method, temperature-assisted on-column solute focusing (TASF), that is capable of focusing large volume injections of small molecules and peptides under gradient conditions. By injecting a large sample volume while cooling a short segment of the column inlet at subambient temperatures, solutes are concentrated into narrow bands at the head of the column. Rapidly raising the temperature of this segment of the column leads to separations with less peak broadening in comparison to solvent focusing alone. For large volume injections of both mixtures of small molecules and a bovine serum albumin tryptic digest, TASF improved the peak shape and resolution in chromatograms. TASF showed the most dramatic improvements with shallow gradients, which is particularly useful for biological applications. Results demonstrate the ability of TASF with gradient elution to improve the sensitivity, resolution, and peak capacity of volume overloaded samples beyond gradient compression alone. Additionally, we have developed and validated a double extrapolation method for predicting retention factors at extremes of temperature and mobile phase composition. Using this method, the effects of TASF can be predicted, allowing determination of the usefulness of this technique for a particular application.

Indexed as

Chromatography, Reverse-PhaseKetonesParabensPeptidesSensitivity and SpecificitySolutionsTemperatureKetonesParabensPeptidesSolutions

Identifiers

PMID27033165
PMCPMC4940048
OpenAlexW2315087934

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.