Evidence map›Paper›PMID 27028383›Full record

ArticleOrthopaedic surgery2016

Effect of a New Annular Incision on Biomechanical Properties of the Intervertebral Disc.

Ling-jie Fu, Chang-sheng Chen, You-zhuan Xie, Jian-wei Yang, Xiao-jiang Sun, Pu Zhang

Abstract readComparative Study
In one paragraph

Article in Orthopaedic surgery, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Ling-jie FuDepartment of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
Chang-sheng ChenCollege of Mechanical and Electrical Engineering, Hohai University, Changzhou, China.
You-zhuan XieDepartment of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
Jian-wei YangDepartment of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
Xiao-jiang SunDepartment of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.
Pu ZhangDepartment of Orthopaedic Surgery, Shanghai Ninth People's Hospital, Shanghai Jiaotong University School of Medicine, Shanghai, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo compare the biomechanical properties of a novel annular incision technique, an oblique incision made approximately 60° to the spinal column, with the traditional transverse and longitudinal annular slit incision in an ex vivo sheep lumbar spine model.

methodsSixteen sheep lumbar spines were used for the current ex vivo biomechanical comparative study. Functional spine unit (FSU) specimens composed of two vertebrae and one disc in the middle was cut from the whole lumbar spine. Annular slit incisions of 5 mm were made in different directions with a 15-blade knife at the intervertebral disc, following which partial discectomy was performed to produce the following groups: control with no incision, transverse slit, longitudinal slit and oblique slit groups. The specimens were then subjected to flexion-extension, lateral bending, axial rotation and compression tests.

resultsAs expected, the control group showed the least range of motion (ROM) in the flexion-extension test. The oblique slit group showed a trend toward a smaller ROM than the transverse and longitudinal groups in 1, 2, 3 and 5 Nm flexion-extension tests; these differences were not statistically significant (P > 0.05). In addition, the transverse (5.80° ± 0.20°), longitudinal (5.77° ± 0.67°) and oblique (5.47° ± 0.43°) slit groups showed a significantly larger ROM than the control group (3.22° ± 0.28°) in 2 Nm lateral bending tests (P < 0.05). Compared with the transverse and longitudinal groups, the oblique group also showed a trend toward a smaller ROM in lateral bending tests (P > 0.05). Following increments in the axial torsion force, the ROM was greater in all four experimental groups than the ROM with 1 Nm axial torsion. Furthermore, a significantly smaller axial rotational ROM was found in the oblique than the transverse group for 1 and 5 Nm force (P < 0.05). With increase in the axial force to 5 Nm, the ROM in the oblique slit group (4.71° ± 0.52°) was significantly smaller than that in the transverse group (7.25° ± 0.46°, P < 0.05), but not significantly different from that of the longitudinal slit group (5.84° ± 0.23°, P > 0.05). Comparable ultimate loads to failure were found in the oblique, transverse and longitudinal groups; the highest ultimate load to failure being in the control group (P > 0.05).

conclusionThe novel oblique slit annular incision to the intervertebral disc showed a trend toward better biomechanical properties than the traditional transverse and longitudinal slit incisions.

Indexed as

AnimalsBiomechanical PhenomenaDiskectomyIntervertebral DiscLumbar VertebraeRandom AllocationRange of Motion, ArticularSheepAnnular incisionBiomechanicsDiscectomyIntervertebral discSheep

Identifiers

PMID27028383
PMCPMC6584100

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.