Evidence map›Paper›PMID 27026920›Full record

ArticleSpringerPlus2016

Simulation of a computed HbA1c using a weighted average glucose.

W Boutayeb, A Boutayeb, M Lamlili, S Ben El Mostafa, N Zitouni

Abstract read
In one paragraph

Article in SpringerPlus, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Remote capillary blood collection for HbADiabetic medicine : a journal of the British Diabetic Association · 2022
    Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

W BoutayebURAC04, LaMSD, Department of Mathematics and Informatics, Faculty of Sciences, University Mohamed Ist, Oujda, Morocco.
A BoutayebURAC04, LaMSD, Department of Mathematics and Informatics, Faculty of Sciences, University Mohamed Ist, Oujda, Morocco.
M LamliliURAC04, LaMSD, Department of Mathematics and Informatics, Faculty of Sciences, University Mohamed Ist, Oujda, Morocco.
S Ben El MostafaISPITS Oujda Annex Nador, Health Ministry, Oujda, Morocco.
N ZitouniHealth Ministry, Oujda, Morocco.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe A1c-derived average glucose examined the link between the glycated haemoglobin and the estimated average glucose, and provided a linear relation between them. Other studies proved that, over a period of 4 months, plasma glucose in the preceding 30 days contribute to about 50 % to the glycated haemoglobin value while the other 50 % is due to the remaining 3 months altogether. TECHNICAL DETAILS OF THE

methodIn this technical note, we propose a weighted method assuming that the contribution of glucose to glycated haemoglobin over 3 months is chronologically 20 %, 30 % and 50 % respectively. A comparison is made with the linear regression method which uses the same estimated average glucose over the whole period. Results yielded by the weighted method are also compared to those given by the model proposed by Ladyzyński et al.

findingsA simulation is carried out on data assumed to come from a first individual with nearly the same level of glucose over 3 months, a second individual who starts with high levels of glucose and then reaches a stabilised low level by the last month, and finally, a third case who had just been diagnosed with diabetes during the last month whereas he/she had a normal glycaemia during the preceding 2 months. The weighted method gives more realistic values of HbA1c (7.36 %, 6.80 %, 8.49 %) than the linear regression method without weights which gives the same value (7.45 %) for the three cases. Another comparison shows that the three values given by the weighted method are slightly smaller than the corresponding values given by the model of Ladyzynski et al. (7.62 %, 7.02 %, 8.8 %) but the relative variation is nearly the same for the three values (≈3 %). CONCLUSSION: Without regular self-testing and day-to-day insights, a sole HbA1c value can be confusing and misleading. For physicians and patients, a clear understanding of the relationship between the weighted average glucose and HbA1c is necessary in order to set an appropriate daily control depending on whether the glucose is stabilized over the whole period, at the beginning, at the end; or still under recurrent episodes of high and low levels. The measured HbA1c at a biological laboratory gives no indication on glucose variation. Moreover, low values of glucose may cancel high values and lead to a "good" average glucose and ideal glycated haemoglobin.

Indexed as

Average glucoseDiabetesGlycated haemoglobinHbA1cWeighted method

Identifiers

PMID27026920
PMCPMC4771657

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.