Evidence map›Paper›PMID 27022206›Full record

ArticleSensors and actuators. B, Chemical2016

Development of a Hydrogen Sulfide End-of-Service-Life Indicator for Respirator Cartridges Using Cobinamide.

Lee A Greenawald, Gerry R Boss, Aaron Reeder, Suzanne Bell

Open access · greenAbstract read
In one paragraph

Article in Sensors and actuators. B, Chemical, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.7field-weighted citation impact, top 29% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 9 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 3 institutions in 1 country.

Lee A Greenawald
Gerry R Boss
Aaron Reeder
Suzanne Bell
National Institute for Occupational Safety and Health · USUniversity of California, San Diego · USWest Virginia University · US

Funding

Pre-Clinical and Clinical Studies of Cobinamide, A New Cyanide Detoxifying AgentU01NS058030 · NINDS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI BOSS, GERRY R · 2006 to 2017
$7.3M
Development of the Vitamin B12 Analog cobinamide as a Hydrogen Sulfide AntidoteU01NS087964 · NINDS · UNIVERSITY OF CALIFORNIA, SAN DIEGO · PI BOSS, GERRY R · 2015 to 2019
$4.3M
NINDS NIH HHS U01 NS058030NINDS NIH HHS U01 NS087964
6 · The paper itself

Abstract

An inexpensive paper-based sensor was developed for detecting low ppm concentrations of hydrogen sulfide gas. A piece of filter paper containing aquohydroxocobinamide [OH(H2O)Cbi] was placed on the end of a bifurcated optical fiber, and the reflectance spectrum of the OH(H2O)Cbi was monitored during exposure to 10.0 ppm hydrogen sulfide gas (NIOSH recommended exposure limit). Reaction of sulfide (HS-) yielded an increase in reflectance from 400-450 nm, and decrease from 470-550 nm. Spectral changes were monitored as a function of time at 25, 50, and 85% relative humidity. Spectral shifts at high-er humidity suggested reduction of the Cbi(III) compound. The sensor was used to detect hydrogen sulfide breakthrough from respirator carbon beds and results correlated well with a standard electrochemical detector. The simple paper-based sensor could provide a real-time end-of-service-life alert for hydrogen sulfide gas.

Indexed as

AquohydroxocobinamideDiffuse ReflectanceEnd-of-Service-Life IndicatorHydrogen SulfideOptical Sensor

Identifiers

PMID27022206
PMCPMC4807636
OpenAlexW2288430646

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.