Evidence map›Paper›PMID 27020001›Full record

ArticleLasers in surgery and medicine2016

Optic nerve sheath fenestration using a Raman-shifted alexandrite laser.

John Kozub, Jin H Shen, Karen M Joos, Ratna Prasad, M Shane Hutson

Open access · greenAbstract read
In one paragraph

Article in Lasers in surgery and medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 89% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 2 institutions in 1 country.

John KozubDepartment of Physics & Astronomy, Vanderbilt University, Nashville, 37235, Tennessee.
Jin H ShenVanderbilt Eye Institute, Vanderbilt University, Nashville, 37232, Tennessee.
Karen M JoosVanderbilt Eye Institute, Vanderbilt University, Nashville, 37232, Tennessee.
Ratna PrasadVanderbilt Eye Institute, Vanderbilt University, Nashville, 37232, Tennessee.
M Shane HutsonDepartment of Physics & Astronomy, Vanderbilt University, Nashville, 37235, Tennessee.
Vanderbilt University · USVanderbilt Health · US

Funding

Shop Module CoreP30EY008126 · NEI · VANDERBILT UNIVERSITY MEDICAL CENTER · PI Kevin L Schey · 1989 to 2026
$19.6M
A Clinically Practical Laser System for NeurosurgeryR44RR024070 · NCRR · LIGHT AGE, INC. · PI HELLER, DONALD F. · 2010 to 2011
$749k
NCRR NIH HHS 2R44RR024070-02A1NCRR NIH HHS R44 RR024070NEI NIH HHS 5P30 EY08126-27NEI NIH HHS P30 EY008126
6 · The paper itself

Abstract

BACKGROUND AND

objectiveOptic nerve sheath fenestration is an established procedure for relief of potentially damaging overpressure on the optic nerve resulting from idiopathic intracranial hypertension. Prior work showed that a mid-IR free-electron laser could be delivered endoscopically and used to produce an effective fenestration. This study evaluates the efficacy of fenestration using a table-top mid-IR source based on a Raman-shifted alexandrite (RSA) laser. STUDY DESIGN/MATERIALS AND

methodsPorcine optic nerves were ablated using light from an RSA laser at wavelengths of 6.09, 6.27, and 6.43 μm and pulse energies up to 3 mJ using both free-space and endoscopic beam delivery through 250-μm I.D. hollow-glass waveguides. Waveguide transmission was characterized, ablation thresholds and etch rates were measured, and the efficacy of endoscopic fenestration was evaluated for ex vivo exposures using both optical coherence tomography and histological analysis.

resultsUsing endoscopic delivery, the RSA laser can effectively fenestrate porcine optic nerves. Performance was optimized at a wavelength of 6.09 μm and delivered pulse energies of 0.5-0.8 mJ (requiring 1.5-2.5 mJ to be incident on the waveguide). Under these conditions, the ablation threshold fluence was 0.8 ± 0.2 J/cm(2) , the ablation rate was 1-4 μm/pulse, and the margins of ablation craters showed little evidence of thermal or mechanical damage. Nonetheless, nominally identical exposures yielded highly variable ablation rates. This led to fenestrations that ranged from too deep to too shallow-either damaging the underlying optic nerve or requiring additional exposure to cut fully through the sheath. Of 48 excised nerves subjected to fenestration at 6.09 μm, 16 ex vivo fenestrations were judged as good, 23 as too deep, and 9 as too shallow.

conclusionsMid-IR pulses from the RSA laser, propagated through a flexible hollow waveguide, are capable of cutting through porcine optic nerve sheaths in surgically relevant times with reasonable accuracy and low collateral damage. This can be accomplished at wavelengths of 6.09 or 6.27 μm, with 6.09 μm slightly preferred. The depth of ex vivo fenestrations was difficult to control, but excised nerves lack a sufficient layer of cerebrospinal fluid that would provide an additional margin of safety in actual patients.

Indexed as

AnimalsDecompression, SurgicalEndoscopyLasers, Solid-StateNerve Compression SyndromesNeurosurgical ProceduresOptic NervePseudotumor CerebriSpectrum Analysis, RamanSwineablationfree-electron laseridiopathic intracranial hypertensionlaser surgerymid-infraredpseudotumor cerebri

Identifiers

PMID27020001
PMCPMC5058430
OpenAlexW2192064078

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.