Evidence map›Paper›PMID 27017285›Full record

ArticleJournal of the mechanical behavior of biomedical materials2016

Mechanical degradation of TiO2 nanotubes with and without nanoparticulate silver coating.

Anish Shivaram, Susmita Bose, Amit Bandyopadhyay

Abstract read
In one paragraph

Article in Journal of the mechanical behavior of biomedical materials, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
2.8field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 40 citations in OpenAlex.

  1. Article
  2. Article
  3. Review
  4. Article
  5. Article
  6. Article
  7. Silver nanoparticle deposited implants to treat osteomyelitis.Journal of biomedical materials research. Part B, Applied biomaterials · 2018
    Article
  8. Review
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 1 institution in 1 country.

Anish ShivaramW. M. Keck Biomedical Materials Research Laboratory, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164-2920, USA.
Susmita BoseW. M. Keck Biomedical Materials Research Laboratory, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164-2920, USA.
Amit BandyopadhyayW. M. Keck Biomedical Materials Research Laboratory, School of Mechanical and Materials Engineering, Washington State University, Pullman, WA 99164-2920, USA. Electronic address: amitband@wsu.edu.
Washington State University · US

Funding

3D Printed Surface Modified Porous Metal Coatings for Load-Bearing ImplantsR01AR067306 · NIAMS · WASHINGTON STATE UNIVERSITY · PI BANDYOPADHYAY, AMIT · 2015 to 2019
$1.8M
NIAMS NIH HHS R01 AR067306
6 · The paper itself

Abstract

The primary objective of this research was to evaluate the extent of mechanical degradation on TiO2 nanotubes on Ti with and without nano-particulate silver coating using two different lengths of TiO2 nanotubes-300nm and ~1µm, which were fabricated on commercially pure Titanium (cp-Ti) rods using anodization method using two different electrolytic mediums-(1) deionized (DI) water with 1% HF, and (2) ethylene glycol with 1% HF, 0.5wt% NH4F and 10% DI water. Nanotubes fabricated rods were implanted into equine cadaver bone to evaluate mechanical damage at the surface. Silver was electrochemically deposited on these nanotubes and using a release study, silver ion concentrations were measured before and after implantation, followed by surface characterization using a Field Emission Scanning Electron Microscope (FESEM). In vitro cell-material interaction study was performed using human fetal osteoblast cells (hFOB) to understand the effect of silver coating using an MTT assay for proliferation and to determine any cytotoxic effect on the cells and to study its biocompatibility. No significant damage due to implantation was observed for nanotubes up to ~1µm length under current experimental conditions. Cell-materials interaction showed no cytotoxic effects on the cells due to silver coating and anodization of samples.

Indexed as

AnimalsBiocompatible MaterialsCells, CulturedHorsesHumansMaterials TestingMetal NanoparticlesNanotubesOsteoblastsSilverSurface PropertiesTitaniumBiocompatible MaterialsSilverTitaniumtitanium dioxideBone implantsCytotoxicityMechanical damageSilver coatingTiO(2) nanotubes

Identifiers

PMID27017285
PMCPMC4860156
OpenAlexW2292227847

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked