Evidence map›Paper›PMID 27001219›Full record

ArticleAmerican journal of obstetrics and gynecology2016

Textile properties of synthetic prolapse mesh in response to uniaxial loading.

William R Barone, Pamela A Moalli, Steven D Abramowitch

Open access · greenAbstract read
In one paragraph

Article in American journal of obstetrics and gynecology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 31 papers.

0numbers the graph read from it
0cells of the map it votes in
31citing papers in PubMed
5.7field-weighted citation impact, top 4% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

31 citing papers in PubMed, 58 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 3 institutions in 1 country.

William R BaroneMusculoskeletal Research Center, Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA.
Pamela A MoalliMagee-Womens Research Institute, Magee-Womens Hospital, University of Pittsburgh, Pittsburgh, PA.
Steven D AbramowitchMusculoskeletal Research Center, Department of Bioengineering, University of Pittsburgh, Pittsburgh, PA; Magee-Womens Research Institute, Magee-Womens Hospital, University of Pittsburgh, Pittsburgh, PA. Electronic address: sdast9@pitt.edu.
Magee-Womens Hospital · USMagee-Womens Research Institute · USUniversity of Pittsburgh · US

Funding

Building Research Careers in Women's HealthK12HD043441 · NICHD · MAGEE-WOMEN'S RES INST AND FOUNDATION · PI SADOVSKY, YOEL · 2002 to 2023
$10.1M
Porosity and tensioning: Critical factors to consider when choosing a prolapse meshR01HD083383 · NICHD · MAGEE-WOMEN'S RES INST AND FOUNDATION · PI ABRAMOWITCH, STEVEN D, MOALLI, PAMELA A. · 2016 to 2025
$5.5M
Comprehensive Evaluation of Prolapse Meshes by an Interdisciplinary Research TeamR01HD061811 · NICHD · MAGEE-WOMEN'S RES INST AND FOUNDATION · PI MOALLI, PAMELA A. · 2009 to 2013
$2.1M
NICHD NIH HHS K12 HD043441NICHD NIH HHS R01 HD061811NICHD NIH HHS R01 HD083383
6 · The paper itself

Abstract

backgroundAlthough synthetic mesh is associated with superior anatomic outcomes for the repair of pelvic organ prolapse, the benefits of mesh have been questioned because of the relatively high complication rates. To date, the mechanisms that result in such complications are poorly understood, yet the textile characteristics of mesh products are believed to play an important role. Interestingly, the pore diameter of synthetic mesh has been shown to impact the host response after hernia repair greatly, and such findings have served as design criteria for prolapse meshes, with larger pores viewed as more favorable. Although pore size and porosity are well-characterized before implantation, the changes in these textile properties after implantation are unclear; the application of mechanical forces has the potential to greatly alter pore geometries in vivo. Understanding the impact of mechanical loading on the textile properties of mesh is essential for the development of more effective devices for prolapse repair.

objectiveThe objective of this study was to determine the effect of tensile loading and pore orientation on mesh porosity and pore dimensions. STUDY

designIn this study, the porosity and pore diameter of 4 currently available prolapse meshes were examined in response to uniaxial tensile loads of 0.1, 5, and 10 N while mimicking clinical loading conditions. The textile properties were compared with those observed for the unloaded mesh. Meshes included Gynemesh PS (Ethicon, Somerville, NJ), UltraPro (Artisyn; Ethicon), Restorelle (Coloplast, Minneapolis, MN), and Alyte Y-mesh (Bard, Covington, GA). In addition to the various pore geometries, 3 orientations of Restorelle (0-, 5-, 45-degree offset) and 2 orientations of UltraPro (0-, 90-degree offset) were examined.

resultsIn response to uniaxial loading, both porosity and pore diameter dramatically decreased for most mesh products. The application of 5 N led to reductions in porosity for nearly all groups, with values decreasing by as much as 87% (P < .05). On loading to 10 N of force, nearly all mesh products that were tested were found to have porosities that approached 0% and 0 pores with diameters >1 mm.

conclusionIn this study, it was shown that the pore size of current prolapse meshes dramatically decreases in response to mechanical loading. These findings suggest that prolapse meshes, which are more likely to experience tensile forces in vivo relative to hernia repair meshes, have pores that are unfavorable for tissue integration after surgical tensioning and/or loading in urogynecologic surgeries. Such decreases in pore geometry support the hypothesis that regional increases in the concentration of mesh leads to an enhanced local foreign body response. Although pore deformation in transvaginal meshes requires further characterization, the findings presented here provide a mechanical understanding that can be used to recognize potential areas of concern for complex mesh geometries. Understanding mesh mechanics in response to surgical and in vivo loading conditions may provide improved design criteria for mesh and a refinement of surgical techniques, ultimately leading to better patient outcomes.

Indexed as

Surgical MeshTensile StrengthWeight-BearingBiomechanical PhenomenaFemaleHumansMaterials TestingPelvic Organ ProlapsePorosityTextilespore diameterporosityprolapsesynthetic mesh

Identifiers

PMID27001219
PMCPMC5161096
OpenAlexW2299829704

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.