Pediatric thoracic CT angiography at 70 kV: a phantom study to investigate the effects on image quality and radiation dose.

Robert D MacDougall, Patricia L Kleinman, Lifeng Yu, Edward Y Lee

Abstract read
PubMed Publisher
In one paragraph

Article in Pediatric radiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Robert D MacDougallDepartment of Radiology, Harvard Medical School, Boston Children's Hospital, 300 Longwood Ave., Boston, MA, 02115, USA. robert.d.macdougall@childrens.harvard.edu.
Patricia L KleinmanDepartment of Radiology, Harvard Medical School, Boston Children's Hospital, 300 Longwood Ave., Boston, MA, 02115, USA.
Lifeng YuDepartment of Radiology, Mayo Clinic, Rochester, MN, USA.
Edward Y LeeDepartment of Radiology, Harvard Medical School, Boston Children's Hospital, 300 Longwood Ave., Boston, MA, 02115, USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundStudies have demonstrated that 70-kilovolt (kV) imaging enhances the contrast of iodine, potentially affording a reduction in radiation dose while maintaining the contrast-to-noise ratio (CNR). There is a maximum amount of image noise beyond which increased contrast does not improve structure visualization. Thus, noise should be constrained during protocol optimization.

objectiveThis phantom study investigated the effect of 70-kV imaging for pediatric thoracic CT angiography on image quality and radiation dose in a pediatric population when a noise constraint was considered. MATERIALS AND

methodsWe measured contrast and noise using anthropomorphic thoracic phantoms ranging in size from newborn age equivalent to 10-year-old age equivalent. We inserted contrast rods into the phantoms to simulate injected contrast material used in a CT angiography study. The image-quality metric "iodine CNR with a noise constraint" was used to determine the relative dose factor for each phantom size, kV setting (70-140 kV) and noise constraint (1.00-1.20). A noise constraint of 1.20 indicates that noise should not increase by more than 20% of the noise level in images performed at the reference kV, selected to be 80 kV in this study. The relative dose factor can be applied to the original dose obtained at 80 kV in order to maintain iodine CNR with the noise constraint. A relative dose factor <1.0 indicates potential for dose reduction while a relative dose factor >1.0 indicates a dose penalty.

resultsIodine contrast was highest for 70 kV and decreased with higher kV settings for all phantom sizes. The relative dose factor at 70 kV was <1.0 for all noise constraint >1.0, indicating potential for dose reduction, for the newborn, 1-year-old and 5-year-old age-equivalent phantom sizes. For the 10-year-old age-equivalent phantom, relative dose factor at 70 kV=1.22, 1.11, 1.01, 0.92 and 0.83 for noise constraint=1.00, 1.05, 1.10, 1.15, 1.20, respectively, indicating a dose penalty for noise constraint ≤1.10 and potential for dose reduction for noise constraint >1.10.

conclusionUsing 70 kV does allow for radiation dose reduction if the radiologist is willing to accept a higher level of image noise as a trade-off for increased vessel contrast. This increase in noise is small (<5%) for the nominal newborn, 1- and 5-year-old but is >10% for the 10-year-old. Therefore, we recommend limiting 70 kV thoracic CT angiography to newborn through 5-year-old patients.

Indexed as

Phantoms, ImagingRadiation DosageChildChild, PreschoolComputed Tomography AngiographyContrast MediaHumansInfantInfant, NewbornIodineRadiographic Image EnhancementRadiographic Image Interpretation, Computer-AssistedRadiography, ThoracicSignal-To-Noise RatioContrast MediaIodine70 kVChildrenComputed tomographyDose reductionPhantom