ArticleThe Journal of bone and joint surgery. American volume2016
Dynamic Stabilization with Active Locking Plates Delivers Faster, Stronger, and More Symmetric Fracture-Healing.
Article in The Journal of bone and joint surgery. American volume, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 32 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
32 citing papers in PubMed, 1 synthesis or guideline pooled it, 84 citations in OpenAlex.
- Dynamic Fracture Fixation Plates: A Systematic Review of Evolving Design Approaches.Annals of biomedical engineering · 2025Pooled it
- Flexure-Based Locking Plates Can Modulate Interfragmentary Motion in Distal Femur and Diaphyseal Fractures: A Parametric Finite Element Analysis.Journal of biomechanical engineering · 2026Article
- Finite element andFrontiers in bioengineering and biotechnology · 2026Article
- Do Far Cortical Locking Screws in Locking Plates Lead to Earlier and Increased Medial Callus in Distal Femur Fractures Comparing to Standard Locking Screws?The Iowa orthopaedic journal · 2026Article
- Far cortical locking versus standard locking screw fixation in simulated femoral fractures: A biomechanical meta-analysis.Journal of orthopaedics · 2025Review
- Does Fixation Method Affect the Correlation of mRUST and Healing Strength?The Iowa orthopaedic journal · 2025Article
- Mechanically compliant locking plates for diaphyseal fracture fixation: A biomechanical study.Journal of orthopaedic research : official publication of the Orthopaedic Research Society · 2025Article
- Advances in Dynamization of Plate Fixation to Promote Natural Bone Healing.Journal of clinical medicine · 2024Review
- Biomechanics of fracture healing: how best to optimize your construct in the OR.OTA international : the open access journal of orthopaedic trauma · 2024Article
- Comparative study of a novel proximal femoral bionic nail and three conventional cephalomedullary nails for reverse obliquity intertrochanteric fractures: a finite element analysis.Frontiers in bioengineering and biotechnology · 2024Article
- Promoting bone callus formation by taking advantage of the time-dependent fracture gap strain modulation.Frontiers in surgery · 2024Review
- Fixators dynamization for delayed union and non-union of femur and tibial fractures: a review of techniques, timing and influence factors.Journal of orthopaedic surgery and research · 2023Review
- Distal femur fractures management and evolution in the last century.International orthopaedics · 2023Review
- Early peri-implant fractures after distal femur fracture locked plating?European journal of orthopaedic surgery & traumatology : orthopedie traumatologie · 2023Article
- Combined electric and magnetic field therapy for bone repair and regeneration: an investigation in a 3-mm and an augmented 17-mm tibia osteotomy model in sheep.Journal of orthopaedic surgery and research · 2023Article
- The Evolution, Current State and Clinical Benefits of Far Cortical Fracture Fixation.The Iowa orthopaedic journal · 2023Article
- Outcomes of the First Generation Locking Plate and Minimally Invasive Techniques Used for Fractures About the Knee.The Iowa orthopaedic journal · 2023Article
- In silico biomechanical analysis of poller screw-assisted small-diameter intramedullary nail in the treatment of distal tibial fractures.Frontiers in bioengineering and biotechnology · 2023Article
- Posterior spinal instrumentation and decompression with or without cross-link?North American Spine Society journal · 2021Article
- Strategies to Improve Bone Healing: Innovative Surgical Implants Meet Nano-/Micro-Topography of Bone Scaffolds.Biomedicines · 2021Review
Corrections and comments
- Commented on by
Authors and funding
9 authors at 4 institutions in 4 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundAxial dynamization of fractures can promote healing, and overly stiff fixation can suppress healing. A novel technology, termed active plating, provides controlled axial dynamization by the elastic suspension of locking holes within the plate. This prospective, controlled animal study evaluated the effect of active plates on fracture-healing in an established ovine osteotomy model. We hypothesized that symmetric axial dynamization with active plates stimulates circumferential callus and delivers faster and stronger healing relative to standard locking plates.
methodsTwelve sheep were randomly assigned to receive a standard locking plate or an active locking plate for stabilization of a 3-mm tibial osteotomy gap. The only difference between plates was that locking holes of active plates were elastically suspended, allowing up to 1.5 mm of axial motion at the fracture. Fracture-healing was analyzed weekly on radiographs. After sacrifice at nine weeks postoperatively, callus volume and distribution were assessed by computed tomography. Finally, to determine their strength, healed tibiae and contralateral tibiae were tested in torsion until failure.
resultsAt each follow-up, the active locking plate group had more callus (p < 0.001) than the standard locking plate group. At postoperative week 6, all active locking plate group specimens had bridging callus at the three visible cortices. In standard locking plate group specimens, only 50% of these cortices had bridged. Computed tomography demonstrated that all active locking plate group specimens and one of the six standard locking plate group specimens had developed circumferential callus. Torsion tests after plate removal demonstrated that active locking plate group specimens recovered 81% of their native strength and were 399% stronger than standard locking plate group specimens (p < 0.001), which had recovered only 17% of their native strength. All active locking plate group specimens failed by spiral fracture outside the callus zone, but standard locking plate group specimens fractured through the osteotomy gap.
conclusionsSymmetric axial dynamization with active locking plates stimulates circumferential callus and yields faster and stronger healing than standard locking plates. CLINICAL RELEVANCE: The stimulatory effect of controlled motion on fracture-healing by active locking plates has the potential to reduce healing complications and to shorten the time to return to function.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.