Evidence map›Paper›PMID 26983944›Full record

Observational studyBMJ open2016

Performance of a non-contact infrared thermometer in healthy newborns.

Sara Sollai, Carlo Dani, Elettra Berti, Claudia Fancelli, Luisa Galli, Maurizio de Martino, Elena Chiappini

Open access · goldAbstract readComparative StudyObservational Study
In one paragraph

Observational study in BMJ open, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 17 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
17citing papers in PubMed, 1 pooled it
3.1field-weighted citation impact, top 9% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

17 citing papers in PubMed, 1 synthesis or guideline pooled it, 48 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Observational
  9. Review
  10. Observational
  11. Article
  12. Non-contact infrared versus axillary and tympanic thermometers in children attending primary care: a mixed-methods study of accuracy and acceptability.The British journal of general practice : the journal of the Royal College of General Practitioners · 2020
    Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Observational
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Sara SollaiDepartment of Health Sciences, University of Florence, Anna Meyer Children's University Hospital, Florence, Italy.ORCID http://orcid.org/0000-0001-5003-993X
Carlo DaniDepartment of Neuroscience, Psychology, Drug Research and Child Health, Careggi University Hospital, Florence, Italy.
Elettra BertiDepartment of Health Sciences, University of Florence, Anna Meyer Children's University Hospital, Florence, Italy.
Claudia FancelliDepartment of Health Sciences, University of Florence, Anna Meyer Children's University Hospital, Florence, Italy.
Luisa GalliDepartment of Health Sciences, University of Florence, Anna Meyer Children's University Hospital, Florence, Italy.
Maurizio de MartinoDepartment of Health Sciences, University of Florence, Anna Meyer Children's University Hospital, Florence, Italy.
Elena ChiappiniDepartment of Health Sciences, University of Florence, Anna Meyer Children's University Hospital, Florence, Italy.
Meyer Children's Hospital · ITAzienda Ospedaliero-Universitaria Careggi · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo evaluate the performance of a non-contact infrared thermometer (NCIT) in comparison with digital axillary thermometer (DAT) and infrared tympanic thermometers (ITT) in a population of healthy at term and preterm newborns nursed in incubators.

setting1 level III maternity hospital, and its intensive neonatal care unit.

participants119 healthy at term newborns and 70 preterm newborns nursed in incubators were consecutively enrolled. Exclusion criteria were unstable/critical conditions, polymalformative congenital syndromes and severe congenital syndromes.

interventionsBody temperature readings were prospectively collected. Each participant underwent bilateral axillary temperature measurement with DAT, bilateral tympanic measurement with ITT and mid-forehead temperature measurements using NCIT. PRIMARY OUTCOME MEASURES: Degree of agreement between methods was evaluated by the Bland and Altman method.

results714 measurements in 119 healthy at term newborns and 420 measurements in 70 preterm newborns nursed in incubators were performed. Clinical reproducibility of NCIT was 0.0455 °C for infants in incubators and 0.0861 °C for infants outside an incubator. Bias was 0.029 °C for infants in incubators and <0.0001 °C for infants outside an incubator. Zero outliers were recorded. The mean difference between methods was good both for newborns at term (0.12 °C for NCIT vs DAT and 0.02 °C for NCIT vs ITT) and preterm newborns in incubators (0.10 °C for NCIT vs DAT and 0.14 °C for NCIT vs ITT). Limits of agreement were 0.99 to -0.75 and 0.78 to -0.75 in at term newborns and were particularly satisfactory in preterm newborns in incubators (95% CI: 0.48 to -0.27 and 0.68 to -0.40).

conclusionsOur results with Bland and Altman analysis demonstrate that NCIT is a very promising tool, especially in preterm newborns nursed in incubators.

trial registrationThe study was approved by the Careggi University Hospital Ethics Committee (07/2011).

Indexed as

Body TemperatureInfrared RaysThermometersAxillaFemaleForeheadHealthy VolunteersHumansInfant, NewbornInfant, PrematureMaleProspective StudiesReproducibility of ResultsThermometryTympanic MembraneNEONATOLOGY

Identifiers

PMID26983944
PMCPMC4800130
OpenAlexW2324199789

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.