ArticleBiomedical optics express2016
Hollow optical-fiber based infrared spectroscopy for measurement of blood glucose level by using multi-reflection prism.
Article in Biomedical optics express, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 13 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
13 citing papers in PubMed, 49 citations in OpenAlex.
- Atomistic Insights into Conformations and Solvation Dynamics of Amylose, Dextran, and Pullulan Using Three Force Fields.The journal of physical chemistry. B · 2026Article
- Noninvasive Analysis of Biological Components Using Simplified Mid-Infrared Photothermal Deflection Spectroscopy.Sensors (Basel, Switzerland) · 2025Article
- Compact Quantum Cascade Laser-Based Noninvasive Glucose Sensor Upgraded with Direct Comb Data-Mining.Sensors (Basel, Switzerland) · 2025Article
- Mid-infrared photoacoustic spectroscopy based on ultrasound detection for blood component analysis.Biomedical optics express · 2023Article
- Is Raman the best strategy towards the development of non-invasive continuous glucose monitoring devices for diabetes management?Frontiers in chemistry · 2022Review
- Infrared measurements of glucose in peritoneal fluid with a tuneable quantum cascade laser.Biomedical optics express · 2020Article
- A Compact Mid-Infrared Spectroscopy System for Healthcare Applications Based on a Wavelength-Swept, Pulsed Quantum Cascade Laser.Sensors (Basel, Switzerland) · 2020Article
- Infrared Spectroscopy with a Fiber-Coupled Quantum Cascade Laser for Attenuated Total Reflection Measurements Towards Biomedical Applications.Sensors (Basel, Switzerland) · 2019Article
- Noninvasive Electromagnetic Wave Sensing of Glucose.Sensors (Basel, Switzerland) · 2019Review
- The Progress of Glucose Monitoring-A Review of Invasive to Minimally and Non-Invasive Techniques, Devices and Sensors.Sensors (Basel, Switzerland) · 2019Review
- Noninvasive glucose monitoring using mid-infrared absorption spectroscopy based on a few wavenumbers.Biomedical optics express · 2018Article
- Glucose-responsive hydrogel electrode for biocompatible glucose transistor.Science and technology of advanced materials · 2017Article
- Mid-Infrared Photoacoustic Detection of Glucose in Human Skin: Towards Non-Invasive Diagnostics.Sensors (Basel, Switzerland) · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A mid-infrared attenuated total reflection (ATR) spectroscopy system employing hollow optical fibers and a trapezoidal multi-reflection ATR prism has been developed to measure blood glucose levels. Using a multi-reflection prism brought about higher sensitivity, and the flat and wide contact surface of the prism resulted in higher measurement reproducibility. An analysis of in vivo measurements of human inner lip mucosa revealed clear signatures of glucose in the difference spectra between ones taken during the fasting state and ones taken after ingestion of glucose solutions. A calibration plot based on the absorption peak at 1155 cm(-1) that originates from the pyranose ring structure of glucose gave measurement errors less than 20%.