Evidence map›Paper›PMID 26975999›Full record

ArticleApplied health economics and health policy2016

Cost-Effectiveness Analysis of Iodine-123 Meta-Iodobenzylguanidine Imaging for Screening Heart Failure Patients Eligible for an Implantable Cardioverter Defibrillator in the USA.

Ken O'Day, Wayne C Levy, Meridith Johnson, Arnold F Jacobson

Open access · hybridAbstract read
In one paragraph

Article in Applied health economics and health policy, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
1.6field-weighted citation impact, top 16% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 16 citations in OpenAlex.

  1. Pooled it
  2. Prognostic usefulness of planarJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Trial
  3. CardiacPharmaceuticals (Basel, Switzerland) · 2022
    Review
  4. How to best appreciate the possible clinical role of cardiacJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2021
    Article
  5. Cardiac sympathetic activity in chronic heart failure: cardiacNetherlands heart journal : monthly journal of the Netherlands Society of Cardiology and the Netherlands Heart Foundation · 2016
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Ken O'DayXcenda, LLC, 4114 Woodlands Parkway, Suite 500, Palm Harbor, FL, 34685, USA. ken.oday@xcenda.com.
Wayne C LevyUniversity of Washington, Seattle, WA, USA.
Meridith JohnsonGE Healthcare US, Princeton, NJ, USA.
Arnold F JacobsonGE Healthcare US, Princeton, NJ, USA.
University of Washington · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundMany guideline-eligible heart failure (HF) patients do not receive a survival benefit from implantable cardioverter defibrillators (ICDs). Improved risk stratification may help to reduce costs and improve the cost effectiveness of ICDs.

objectiveTo estimate the potential outcomes, costs, and cost effectiveness of using iodine-123 meta-iodobenzylguanidine (I-mIBG) to screen HF patients eligible for an ICD.

methodsA decision-analytic model was developed to compare screening with I-mIBG imaging and no screening over 2-year and 10-year time horizons from a US payer perspective. Data on I-mIBG imaging and risk stratification were obtained from the ADMIRE-HF/HFX (AdreView Myocardial Imaging for Risk Evaluation in Heart Failure) trial. Data on ICD effectiveness for prevention of sudden cardiac death (SCD) were obtained from a meta-analysis. Costs of ICDs and costs of generator and lead procedures were obtained from the Agency for Healthcare Research and Quality National Inpatient Sample. Age-specific mortality was modeled using US life tables and data from the ACT (Advancements in ICD Therapy) Registry on risks of SCD and non-SCD mortality. Sensitivity analyses were conducted.

resultsIn the analysis, screening with I-mIBG imaging was associated with a reduction in ICD utilization of 21 %, resulting in a number needed to screen to prevent 1 ICD implantation of 5. Screening reduced the costs per patient by US$5500 and US$13,431 (in 2013 dollars) over 2 and 10 years, respectively, in comparison with no screening and resulted in losses of 0.001 and 0.040 life-years, respectively, over 2 and 10 years. Screening was decrementally cost effective, with savings of US$5,248,404 and US$513,036 per quality-adjusted life-year lost over 2 and 10 years, respectively. In subgroup analyses, cost savings were greater for patients with an ejection fraction (EF) of 25-35 % than for those with an EF <25 %.

conclusionsAccording to the model, screening of guideline-eligible patients selected for ICDs with I-mIBG imaging may be cost effective and may help reduce costs associated with implantation of ICDs, with a minimal impact on survival.

Indexed as

Decision Support Techniques3-IodobenzylguanidineAgedAged, 80 and overCause of DeathCost-Benefit AnalysisDefibrillators, ImplantableFemaleHeart FailureHumansLife TablesMaleMiddle AgedQuality-Adjusted Life YearsRadiopharmaceuticalsRisk Assessment3-IodobenzylguanidineRadiopharmaceuticals

Identifiers

PMID26975999
PMCPMC4871910
OpenAlexW2297125211

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.