ReviewEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery2016
Postoperative pain in patients undergoing a transcutaneous active bone conduction implant (Bonebridge).
Review in European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers, 4 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
20 citing papers in PubMed, 4 syntheses or guidelines pooled it, 49 citations in OpenAlex.
- Pooled it
- Active transcutaneous bone conduction hearing implants: Systematic review and meta-analysis.PloS one · 2019Pooled it
- Guideline
- Guideline
- Piezoelectric Bone Conduction Hearing Implant: A Case Series of Audiological, Surgical and Patient-Reported Outcomes.Journal of clinical medicine · 2024Article
- Review
- BonebridgeEuropean archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2023Article
- Multicentric study on surgical information and early safety and performance results with the Bonebridge BCI 602: an active transcutaneous bone conduction hearing implant.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2023Review
- [Clinical research progress of bonebridge implantation].Lin chuang er bi yan hou tou jing wai ke za zhi = Journal of clinical otorhinolaryngology head and neck surgery · 2022Review
- Long-term audiological benefit with an active transcutaneous bone-conduction device: a retrospective cohort analysis.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2022Article
- Two Bonebridge bone conduction hearing implant generations: audiological benefit and quality of hearing in children.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2022Article
- Clinical and functional results after implantation of the bonebridge, a semi-implantable, active transcutaneous bone conduction device, in children and adults.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2022Article
- MRI after Bonebridge implantation: a comparison of two implant generations.European archives of oto-rhino-laryngology : official journal of the European Federation of Oto-Rhino-Laryngological Societies (EUFOS) : affiliated with the German Society for Oto-Rhino-Laryngology - Head and Neck Surgery · 2021Article
- Planning tools and indications for "virtual surgery" for the Bonebridge bone conduction system.HNO · 2021Review
- Alternative Inverted Middle Fossa Approach in Bonebridge Surgery. Technique, Results and Complications.International archives of otorhinolaryngology · 2021Article
- Review
- Retrosigmoidal placement of an active transcutaneous bone conduction implant: surgical and audiological perspectives in a multicentre study.Acta otorhinolaryngologica Italica : organo ufficiale della Societa italiana di otorinolaringologia e chirurgia cervico-facciale · 2021Article
- The middle fossa approach with self-drilling screws: a novel technique for BONEBRIDGE implantation.Journal of otolaryngology - head & neck surgery = Le Journal d'oto-rhino-laryngologie et de chirurgie cervico-faciale · 2019Article
- Minimal Reporting Standards for Active Middle Ear Hearing Implants.Audiology & neuro-otology · 2018Article
- Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 2 institutions in 2 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The objective of the study was to evaluate postoperative pain following a transcutaneous active conductive hearing implant. 27 patients undergoing Bonebridge (BB) bone conduction implantation were evaluated with two pain-related questionnaires. The Headache Impact Test (HIT-6) was used to measure the degree of disability including none or little impact (≤49), mild (50-55), moderate (56-59), and severe (≥60). The Brief Pain Inventory (BPI) was used to assess pain severity score and function interference (0 = no pain to 10 = worst pain); meaningful pain was considered to be ≥3. The impact of surgical factors on postoperative pain was analyzed. Postoperative BB pain results were compared with 11 Vibrant Soundbridge™ (VSB) and 103 cochlear implant (CI) users. The mean pre- and postoperative HIT-6 scores for BB implantation were 42.6 and 41.8, respectively and the mean preoperative BPI pain severity score changed from 0.6 to 0.9 postoperatively, whereas the preoperative interference score changed from 0.1 to 0.3. None of the mean postoperative values revealed significant pain. The retrosigmoid approach, the need for dural or sinus compression, and the use of bone conduction implant lifts had no significant impact on pain scores. The mean postoperative HIT-6 pain scores for patients with BB, VSB, and CI were 41.8, 46.4, and 42.8, respectively, with the differences not being significant. BB implantation causes no significant postoperative pain irrespective of sinus or dura compression. Pain scores were similar to those experienced by patients with other transcutaneous auditory implants such as middle ear or CIs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.