ArticleBiomicrofluidics2016
A continuous glucose monitoring device by graphene modified electrochemical sensor in microfluidic system.
Article in Biomicrofluidics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 15 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
15 citing papers in PubMed.
- Body Biofluids for Minimally-Invasive Diagnostics: Insights, Challenges, Emerging Technologies, and Clinical Potential.Advanced healthcare materials · 2026Review
- Microfluidic-based systems for the management of diabetes.Drug delivery and translational research · 2024Review
- Epidermal Wearable Biosensors for the Continuous Monitoring of Biomarkers of Chronic Disease in Interstitial Fluid.Micromachines · 2023Review
- Two-Dimensional Transition Metal Dichalcogenide Based Biosensors: From Fundamentals to Healthcare Applications.Biosensors · 2023Review
- Laser induced graphanized microfluidic devices.Biomicrofluidics · 2022Review
- A Review of Recent Advances in Vital Signals Monitoring of Sports and Health via Flexible Wearable Sensors.Sensors (Basel, Switzerland) · 2022Review
- Advanced wearable biosensors for the detection of body fluids and exhaled breath by graphene.Mikrochimica acta · 2022Review
- Integration of Different Graphene Nanostructures with PDMS to Form Wearable Sensors.Nanomaterials (Basel, Switzerland) · 2022Review
- Microfluidic chip connected to porous microneedle array for continuous ISF sampling.Drug delivery and translational research · 2022Article
- A thermal activated and differential self-calibrated flexible epidermal biomicrofluidic device for wearable accurate blood glucose monitoring.Science advances · 2021Article
- Recent Developments of Flexible and Stretchable Electrochemical Biosensors.Micromachines · 2020Review
- A graphene aptasensor for biomarker detection in human serum.Electrochimica acta · 2018Article
- Functionalized microneedles for continuous glucose monitoring.Nano convergence · 2018Review
- Lab-on-chip technology for chronic disease diagnosis.NPJ digital medicine · 2018Review
- Preface to Special Topic: Selected Papers from the 5th International Conference on Optofluidics.Biomicrofluidics · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
This paper presents a continuous glucose monitoring microsystem consisting of a three-electrode electrochemical sensor integrated into a microfluidic chip. The microfluidic chip, which was used to transdermally extract and collect subcutaneous interstitial fluid, was fabricated from five polydimethylsiloxane layers using micromolding techniques. The electrochemical sensor was integrated into the chip for continuous detection of glucose. Specifically, a single-layer graphene and gold nanoparticles (AuNPs) were decorated onto the working electrode (WE) of the sensor to construct a composite nanostructured surface and improve the resolution of the glucose measurements. Graphene was transferred onto the WE surface to improve the electroactive nature of the electrode to enable measurements of low levels of glucose. The AuNPs were directly electrodeposited onto the graphene layer to improve the electron transfer rate from the activity center of the enzyme to the electrode to enhance the sensitivity of the sensor. Glucose oxidase (GOx) was immobilized onto the composite nanostructured surface to specifically detect glucose. The factors required for AuNPs deposition and GOx immobilization were also investigated, and the optimized parameters were obtained. The experimental results displayed that the proposed sensor could precisely measure glucose in the linear range from 0 to 162 mg/dl with a detection limit of 1.44 mg/dl (S/N = 3). The proposed sensor exhibited the potential to detect hypoglycemia which is still a major challenge for continuous glucose monitoring in clinics. Unlike implantable glucose sensors, the wearable device enabled external continuous monitoring of glucose without interference from foreign body reaction and bioelectricity.