ArticleJournal of sports science & medicine2016
The Total Work Measured During a High Intensity Isokinetic Fatigue Test Is Associated With Anaerobic Work Capacity.
Article in Journal of sports science & medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT07636967 (The Relationship Between Chronic Non-Specific Low Back Pain and Isokinetic Performance of Ankle Joint Muscles), which is not on this map. Cited by 8 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
The Relationship Between Chronic Non-Specific Low Back Pain and Isokinetic Performance of Ankle Joint Muscles
Who cites it
8 citing papers in PubMed, 11 citations in OpenAlex.
- Impact of blood flow restriction training timing: Does exercising at dusk or dawn enhance response?Physiological reports · 2025Article
- Machine Learning-Driven Muscle Fatigue Estimation in Resistance Training with Assistive Robotics.Sensors (Basel, Switzerland) · 2025Article
- Age-Related Differences in Adaptation of Lean Body Mass, Muscle Strength, and Performance Following 6 Weeks of Blood Flow Restriction Training in Young and Older Adults.Journal of frailty, sarcopenia and falls · 2025Article
- Impact of exercise with blood flow restriction on muscle hypertrophy and performance outcomes in men and women.PloS one · 2025Article
- Unilateral Maximal Isometric Hex Bar Pull Test: Within-Session Reliability and Lower Body Force Production in Male and Female Freeski Athletes.Frontiers in sports and active living · 2021Article
- Application of ultrasound elastography in the evaluation of muscle strength in a healthy population.Quantitative imaging in medicine and surgery · 2020Article
- Monitoring Exercise-Induced Muscle Fatigue and Adaptations: Making Sense of Popular or Emerging Indices and Biomarkers.Sports (Basel, Switzerland) · 2018Review
- Reproducibility of Blood Lactate Concentration Rate under Isokinetic Force Loads.Sports (Basel, Switzerland) · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 6 institutions in 4 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The purpose of the study was to determine whether total work measured during a high intensity isokinetic fatigue test (TWFAT) could be considered as a valid measure of anaerobic work capacity (AWC), such as determined by total work measured during a Wingate Anaerobic Test (TWWAnT). Twenty well-trained cyclists performed 2 randomly ordered sessions involving a high intensity isokinetic fatigue test consisting in 30 reciprocal maximal concentric contractions of knee flexors and extensors at 180°·s(-1), and a Wingate Anaerobic Test. We found that TWFAT of knee extensors was largely lower than TWWAnT (4151 ± 691 vs 22313 ± 2901 J, respectively, p < 0.05, Hedge's g = 4.27). Both measures were highly associated (r = 0.83), and the 95% limits of agreement (LoA) represented 24.5% of TWWAnT. TWFAT of knee flexors (2151 ± 540 J) was largely lower than TWWAnT (p < 0.05, g = 9.52). By contrast, both measures were not associated (r = 0.09), and the 95% LoA represented 31.1% of TWWAnT. Combining TWFAT of knee flexors and knee extensors into a single measure (6302 ± 818 J) did not changed neither improved these observations. We still found a large difference with TWWAnT (p < 0.05, g = 5.26), a moderate association (r = 0.65) and 95% LoA representing 25.5% of TWWAnT. We concluded that TWFAT of knee extensors could be considered as a valid measure of AWC, since both measure were highly associated. However, the mean difference between both measures and their 95% LoA were too large to warrant interchangeability. Key pointsTotal work performed during a high intensity isokinetic fatigue test can be considered as a valid measure of anaerobic work capacity (as determined by total work performance during a 30-s Wingate anaerobic test).The 95% limits of agreement are two large to allow a direct comparison between both measures. In other words, it is not possible to estimate the magnitude of performance improvement during a 30-s Wingate anaerobic test from that observed during a high intensity isokinetic fatigue test.In addition to provide sport scientists and coaches with measures of peak torque and ratios between agonists and antagonists muscles in a perspective of injury prevention, isokinetic dynamometry can also be used in the physiological assessment of athletes. However, some precautions should be taken in the interpretation of data.
Indexed as
Identifiers
26957935PMC4763831W2429881094What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.