Attenuation Correction for Magnetic Resonance Coils in Combined PET/MR Imaging: A Review.

Mootaz Eldib, Jason Bini, David D Faul, Niels Oesingmann, Charalampos Tsoumpas, Zahi A Fayad

Abstract readReview
In one paragraph

Review in PET clinics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Review
  2. The use of PET/MRI in radiotherapy.Insights into imaging · 2024
    Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Attenuation correction for human PET/MRI studies.Physics in medicine and biology · 2020
    Article
  8. Article
  9. Article
  10. Article
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Mootaz EldibTranslational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029, USA; Department of Biomedical Engineering, The City College of New York, 160 Convent Avenue, New York, NY 10031, USA.
Jason BiniDepartment of Diagnostic Radiology, PET Center, Yale School of Medicine, Yale University, 801 Howard Avenue, New Haven, CT 06520, USA.
David D FaulSiemens Healthcare, 527 Madison Avenue, New York, NY 10022, USA.
Niels OesingmannSiemens Healthcare, 527 Madison Avenue, New York, NY 10022, USA.
Charalampos TsoumpasTranslational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029, USA; Division of Biomedical Imaging, Faculty of Medicine and Health, University of Leeds, 8.001a Worsley Building, Clarendon Way, Leeds LS2 9JT, UK.
Zahi A FayadTranslational and Molecular Imaging Institute, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029, USA; Department of Radiology, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029, USA; Department of Cardiology, Zena and Michael A. Weiner Cardiovascular Institute, Marie-Josée and Henry R. Kravis Cardiovascular Health Center, Icahn School of Medicine at Mount Sinai, One Gustave L. Levy Place, New York, NY 10029, USA. Electronic address: zahi.fayad@mssm.edu.

Funding

MR/PET Imaging of coronary atherosclerosisR01HL071021 · NHLBI · MOUNT SINAI SCHOOL OF MEDICINE OF NYU · PI FAYAD, ZAHI A. · 2002 to 2019
$7.8M
Cardiovascular Inflammation Reduction Trial (CIRT) - Inflammation Imaging StudyR01HL128056 · NHLBI · ICAHN SCHOOL OF MEDICINE AT MOUNT SINAI · PI FAYAD, ZAHI A. · 2015 to 2018
$2.6M
NHLBI NIH HHS R01 HL071021NHLBI NIH HHS R01 HL128056
6 · The paper itself

Abstract

With the introduction of clinical PET/magnetic resonance (MR) systems, novel attenuation correction methods are needed, as there are no direct MR methods to measure the attenuation of the objects in the field of view (FOV). A unique challenge for PET/MR attenuation correction is that coils for MR data acquisition are located in the FOV of the PET camera and could induce significant quantitative errors. In this review, current methods and techniques to correct for the attenuation of a variety of coils are summarized and evaluated.

Indexed as

ArtifactsComputer-Aided DesignEquipment DesignForecastingHumansImage EnhancementMagnetic Resonance ImagingMultimodal ImagingPhantoms, ImagingPositron-Emission TomographyScattering, RadiationAttenuation correctionImage analysisMR imaging surface coilsPET/MR imagingPET/MR reconstructionScatter correction

Identifiers

PMID26952728
PMCPMC4785842

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.