Observational studyEuropean radiology2016
The state of the art in breast imaging using the Twente Photoacoustic Mammoscope: results from 31 measurements on malignancies.
Observational study in European radiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 59 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
59 citing papers in PubMed.
- Assessment of Breast Tumors Using Multispectral Optoacoustic Tomography in a Surgical Setting.Journal of nuclear medicine : official publication, Society of Nuclear Medicine · 2025Trial
- Mapping the research landscape of photoacoustic imaging in breast cancer: a text-based bibliometric analysis.Gland surgery · 2026Article
- High-speed photoacoustic and ultrasonic computed tomography of the breast tumor for early diagnosis with enhanced accuracy.Science advances · 2025Article
- Resolution Enhancement Strategies in Photoacoustic Microscopy: A Comprehensive Review.Micromachines · 2024Review
- Breast Cancer Diagnosis Using Extended-Wavelength-Diffuse Reflectance Spectroscopy (EW-DRS)-Proof of Concept in Ex Vivo Breast Specimens Using Machine Learning.Diagnostics (Basel, Switzerland) · 2023Article
- Biomarkers of aging.Science China. Life sciences · 2023Review
- The application of optical technology in the diagnosis and therapy of oxidative stress-mediated hepatic ischemia-reperfusion injury.Frontiers in bioengineering and biotechnology · 2023Review
- Article
- A Comprehensive Review on Photoacoustic-Based Devices for Biomedical Applications.Sensors (Basel, Switzerland) · 2022Review
- An optoacoustic imaging feature set to characterise blood vessels surrounding benign and malignant breast lesions.Photoacoustics · 2022Article
- Image processing improvements afford second-generation handheld optoacoustic imaging of breast cancer patients.Photoacoustics · 2022Article
- The emerging role of photoacoustic imaging in clinical oncology.Nature reviews. Clinical oncology · 2022Review
- Noninvasive Dual-Modality Photoacoustic-Ultrasonic Imaging to Detect Mammalian Embryo Abnormalities after Prenatal Exposure to Methylmercury Chloride (MMC): A Mouse Study.Environmental health perspectives · 2022Article
- The Potential of Photoacoustic Imaging in Radiation Oncology.Frontiers in oncology · 2022Article
- Perspective on fast-evolving photoacoustic tomography.Journal of biomedical optics · 2021Article
- Photoacoustic dual-scan mammoscope: results from 38 patients.Biomedical optics express · 2021Article
- Role of blood oxygenation saturation in ovarian cancer diagnosis using multi-spectral photoacoustic tomography.Journal of biophotonics · 2021Article
- Exploring the diagnostic value of photoacoustic imaging for breast cancer: the identification of regional photoacoustic signal differences of breast tumors.Biomedical optics express · 2021Article
- Pendant breast immobilization and positioning in photoacoustic tomographic imaging.Photoacoustics · 2021Article
- Three-dimensional view of out-of-plane artifacts in photoacoustic imaging using a laser-integrated linear-transducer-array probe.Photoacoustics · 2020Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectivesPhotoacoustic mammography is potentially an ideal technique, however, the amount of patient data is limited. To further our understanding of the in vivo performance of the method and to guide further research and development, we imaged 33 breast malignancies using the research system - the Twente Photoacoustic Mammoscope (PAM).
methodsThirty-one patients participated in this retrospective, observational study. The study and informed consent procedure were approved by the local ethics committee. PAM uses 1,064 nm light for excitation with a planar, 588-element, 1-MHz ultrasound array for detection. Photoacoustic lesion visibility and appearance were compared with conventional imaging (x-ray mammography and ultrasonography) findings, histopathology and patient demographics.
resultsOf 33 malignancies 32 were visualized with high contrast and good co-localization with conventional imaging. The contrast of the detected malignancies was independent of radiographic breast density, and size estimation was reasonably good with an average 28 % deviation from histology. However, the presence of contrast areas outside the malignant region is suggestive for low specificity of the current system. Statistical analyses did not reveal any further relationship between PAM results and patient demographics nor lesion characteristics.
conclusionsThe results confirm the high potential of photoacoustic mammography in future breast care. KEY POINTS: • Photoacoustic breast imaging visualizes malignancies with high imaging contrast. • Photoacoustic lesion contrast is independent of the mammographically estimated breast density. • No clear relationship exists between photoacoustic characteristics and lesion type, grade, etc. • Photoacoustic specificity to breast cancer from some cases is not yet optimal.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.