Evidence map›Paper›PMID 26945488›Full record

ArticleInternational journal of surgery case reports2016

Successful treatment of recurrent carotid in-stent restenosis and drug-eluting balloon failure with a coronary bioresorbable vascular scaffold: A case report.

Arturo Giordano, Paolo Ferraro, Nicola Corcione, Stefano Messina, Gennaro Maresca, Enrico Coscioni, Giuseppe Biondi-Zoccai

Open access · goldAbstract read
In one paragraph

Article in International journal of surgery case reports, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed, 1 pooled it
1.5field-weighted citation impact, top 17% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 1 synthesis or guideline pooled it, 10 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 1 country.

Arturo GiordanoUnità Operativa di Interventistica Cardiovascolare, Presidio Ospedaliero Pineta Grande, Castel Volturno, Italy; Unità Operativa di Emodinamica, Casa di Salute Santa Lucia, San Giuseppe Vesuviano, Italy.
Paolo FerraroUnità Operativa di Interventistica Cardiovascolare, Presidio Ospedaliero Pineta Grande, Castel Volturno, Italy; Unità Operativa di Emodinamica, Casa di Salute Santa Lucia, San Giuseppe Vesuviano, Italy.
Nicola CorcioneUnità Operativa di Interventistica Cardiovascolare, Presidio Ospedaliero Pineta Grande, Castel Volturno, Italy; Unità Operativa di Emodinamica, Casa di Salute Santa Lucia, San Giuseppe Vesuviano, Italy.
Stefano MessinaUnità Operativa di Interventistica Cardiovascolare, Presidio Ospedaliero Pineta Grande, Castel Volturno, Italy; Unità Operativa di Emodinamica, Casa di Salute Santa Lucia, San Giuseppe Vesuviano, Italy.
Gennaro MarescaUnità Operativa di Interventistica Cardiovascolare, Presidio Ospedaliero Pineta Grande, Castel Volturno, Italy; Unità Operativa di Emodinamica, Casa di Salute Santa Lucia, San Giuseppe Vesuviano, Italy.
Enrico CoscioniDivision of Cardiac Surgery, San Giovanni di Dio e Ruggì D'Aragona Hospital, Salerno, Italy.
Giuseppe Biondi-ZoccaiDepartment of Medico-Surgical Sciences and Biotechnologies, Sapienza University of Rome, Latina, Italy; Department of AngioCardioNeurology, IRCCS Neuromed, Pozzilli, Italy. Electronic address: giuseppe.biondizoccai@uniroma1.it.
Presidio Ospedaliero · ITIstituto Neurologico Mediterraneo · ITOspedali Riuniti San Giovanni di Dio e Ruggi d'Aragona · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionCarotid in-stent restenosis is associated with substantial risk of recurrent restenosis, even after drug-eluting balloon usage. PRESENTATION OF CASE: We hereby report the case of a patient with recurrent carotid in-stent restenosis and drug-eluting balloon failure treated with a coronary bioresorbable vascular scaffold, achieving a satisfactory acute and long-term result, as disclosed by duplex ultrasound scan performed more than 1 year after the procedure. DISCUSSION/

conclusionWhile awaiting for external validation, this clinical vignette supports expanding the armamentarium of endovascular specialists focusing on carotid artery disease, while providing further proof of the safety and efficacy of current bioresorbable vascular scaffolds.

Indexed as

Bioresorbable vascular scaffoldCarotid artery diseaseEndovascular therapyIn-stent restenosis

Identifiers

PMID26945488
PMCPMC4802336
OpenAlexW2284856361

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.