ArticlePhysics in medicine and biology2016
A new scheme for real-time high-contrast imaging in lung cancer radiotherapy: a proof-of-concept study.
Article in Physics in medicine and biology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Deep learning-based Fast Volumetric Image Generation for Image-guided Proton Radiotherapy.IEEE transactions on radiation and plasma medical sciences · 2024Article
- Deep learning-based fast volumetric imaging using kV and MV projection images for lung cancer radiotherapy: A feasibility study.Medical physics · 2023Article
- Experimental and numerical studies on kV scattered x-ray imaging for real-time image guidance in radiation therapy.Physics in medicine and biology · 2021Article
- Deep learning-based real-time volumetric imaging for lung stereotactic body radiation therapy: a proof of concept study.Physics in medicine and biology · 2020Article
- Scatter imaging during lung stereotactic body radiation therapy characterized with phantom studies.Physics in medicine and biology · 2020Article
- Compton scatter imaging: A promising modality for image guidance in lung stereotactic body radiation therapy.Medical physics · 2018Article
- Characterization of Compton-scatter imaging with an analytical simulation method.Physics in medicine and biology · 2018Article
- Magnetic resonance imaging in precision radiation therapy for lung cancer.Translational lung cancer research · 2017Review
- Treatment of esophageal cancer with radiation therapy -a pan-Chinese survey of radiation oncologists.Oncotarget · 2017Article
- Catalytic radiosensitization: Insights from materials physicochemistry.Materials today (Kidlington, England)Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors.
Funding
Abstract
Visualization of anatomy in real time is of critical importance for motion management in lung cancer radiotherapy. To achieve real-time, and high-contrast in-treatment imaging, we propose a novel scheme based on the measurement of Compton scatter photons. In our method, a slit x-ray beam along the superior-inferior direction is directed to the patient, (intersecting the lung region at a 2D plane) containing most of the tumor motion trajectory. X-ray photons are scattered off this plane primarily due to the Compton interaction. An imager with a pinhole or a slat collimator is placed at one side of the plane to capture the scattered photons. The resulting image, after correcting for incoming fluence inhomogeneity, x-ray attenuation, scatter angle variation, and outgoing beam geometry, represents the linear attenuation coefficient of Compton scattering. This allows the visualization of the anatomy on this plane. We performed Monte Carlo simulation studies both on a phantom and a patient for proof-of-principle purposes. In the phantom case, a small tumor-like structure could be clearly visualized. The contrast-resolution calculated using tumor/lung as foreground/background for kV fluoroscopy, cone beam computed tomography (CBCT), and scattering image were 0.037, 0.70, and 0.54, respectively. In the patient case, tumor motion could be clearly observed in the scatter images. Imaging dose to the voxels directly exposed by the slit beam was ~0.4 times of that under a single CBCT projection. These studies demonstrated the potential feasibility of the proposed imaging scheme to capture the instantaneous anatomy of a patient on a 2D plane with a high image contrast. Clear visualization of the tumor motion may facilitate marker-less tumor tracking.