Evidence map›Paper›PMID 26938471›Full record

ArticlePloS one2016

Sensitive and Specific Biomimetic Lipid Coated Microfluidics to Isolate Viable Circulating Tumor Cells and Microemboli for Cancer Detection.

Jia-Yang Chen, Wen-Sy Tsai, Hung-Jen Shao, Jen-Chia Wu, Jr-Ming Lai, Si-Hong Lu, Tsung-Fu Hung, Chih-Tsung Yang, Liang-Chun Wu, Jinn-Shiun Chen and 2 more

Open access · goldAbstract read
In one paragraph

Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 28 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
28citing papers in PubMed, 1 pooled it
7.5field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

28 citing papers in PubMed, 1 synthesis or guideline pooled it, 66 citations in OpenAlex.

  1. Pooled it
  2. Trial
  3. Review
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
  11. Strategies for enrichment of circulating tumor cells.Translational cancer research · 2020
    Review
  12. Article
  13. Microfluidic tools for lipid production and modification: a review.Environmental science and pollution research international · 2019
    Review
  14. Article
  15. Article
  16. Article
  17. Review
  18. Review
  19. Article
  20. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 4 institutions in 1 country.

Jia-Yang ChenGenomics Research Center, Academia Sinica, Nankang, Taipei, Taiwan.
Wen-Sy TsaiDivision of Colon and Rectal Surgery, Chang Gung Memorial Hospital, Kueishan, Taoyuan, Linkou, Taiwan.
Hung-Jen ShaoGenomics Research Center, Academia Sinica, Nankang, Taipei, Taiwan.
Jen-Chia WuGenomics Research Center, Academia Sinica, Nankang, Taipei, Taiwan.
Jr-Ming LaiGenomics Research Center, Academia Sinica, Nankang, Taipei, Taiwan.
Si-Hong LuGenomics Research Center, Academia Sinica, Nankang, Taipei, Taiwan.
Tsung-Fu HungGenomics Research Center, Academia Sinica, Nankang, Taipei, Taiwan.
Chih-Tsung YangGenomics Research Center, Academia Sinica, Nankang, Taipei, Taiwan.
Liang-Chun WuGenomics Research Center, Academia Sinica, Nankang, Taipei, Taiwan.
Jinn-Shiun ChenDivision of Colon and Rectal Surgery, Chang Gung Memorial Hospital, Kueishan, Taoyuan, Linkou, Taiwan.
Wen-Hwa LeeGenomics Research Center, Academia Sinica, Nankang, Taipei, Taiwan.
Ying-Chih ChangGenomics Research Center, Academia Sinica, Nankang, Taipei, Taiwan.
Genomics Research Center, Academia Sinica · TWChang Gung Memorial Hospital · TWChang Gung University · TWNational Defense Medical Center · TW

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Here we presented a simple and effective membrane mimetic microfluidic device with antibody conjugated supported lipid bilayer (SLB) "smart coating" to capture viable circulating tumor cells (CTCs) and circulating tumor microemboli (CTM) directly from whole blood of all stage clinical cancer patients. The non-covalently bound SLB was able to promote dynamic clustering of lipid-tethered antibodies to CTC antigens and minimized non-specific blood cells retention through its non-fouling nature. A gentle flow further flushed away loosely-bound blood cells to achieve high purity of CTCs, and a stream of air foam injected disintegrate the SLB assemblies to release intact and viable CTCs from the chip. Human blood spiked cancer cell line test showed the ~95% overall efficiency to recover both CTCs and CTMs. Live/dead assay showed that at least 86% of recovered cells maintain viability. By using 2 mL of peripheral blood, the CTCs and CTMs counts of 63 healthy and colorectal cancer donors were positively correlated with the cancer progression. In summary, a simple and effective strategy utilizing biomimetic principle was developed to retrieve viable CTCs for enumeration, molecular analysis, as well as ex vivo culture over weeks. Due to the high sensitivity and specificity, it is the first time to show the high detection rates and quantity of CTCs in non-metastatic cancer patients. This work offers the values in both early cancer detection and prognosis of CTC and provides an accurate non-invasive strategy for routine clinical investigation on CTCs.

Indexed as

Lab-On-A-Chip DevicesAdultAntibodiesAntigens, NeoplasmColorectal NeoplasmsEarly Detection of CancerFemaleHCT116 CellsHumansLipidsMaleMiddle AgedNeoplastic Cells, CirculatingAntibodiesAntigens, NeoplasmLipids

Identifiers

PMID26938471
PMCPMC4777486
OpenAlexW2295745129

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.