Evidence map›Paper›PMID 26936366›Full record

ArticleJournal of materials science. Materials in medicine2016

Biological characterization of a new silicon based coating developed for dental implants.

M Martínez-Ibáñez, M J Juan-Díaz, I Lara-Saez, A Coso, J Franco, M Gurruchaga, J Suay Antón, Isabel Goñi

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of materials science. Materials in medicine, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed.

  1. Article
  2. Review of Metallic Biomaterials in Dental Applications.Journal of pharmacy & bioallied sciences · 2020
    Review
  3. Proteomic analysis of calcium-enriched sol-gel biomaterials.Journal of biological inorganic chemistry : JBIC : a publication of the Society of Biological Inorganic Chemistry · 2019
    Article
  4. Osseointegration mechanisms: a proteomic approach.Journal of biological inorganic chemistry : JBIC : a publication of the Society of Biological Inorganic Chemistry · 2018
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

M Martínez-IbáñezPolymer Science and Technology Department, University of the Basque Country (UPV/EHU), P Manuel de Lardizabal, 3, 20018, San Sebastián, Spain.
M J Juan-DíazPolymer Science and Technology Department, University of the Basque Country (UPV/EHU), P Manuel de Lardizabal, 3, 20018, San Sebastián, Spain.
I Lara-SaezIndustrial Systems Engineering and Design Department, Jaime I University (UJI), 12071, Castellón de la Plana, Spain.
A CosoIlerimplant SL, 25191, Lleida, Spain.
J FrancoIlerimplant SL, 25191, Lleida, Spain.
M GurruchagaPolymer Science and Technology Department, University of the Basque Country (UPV/EHU), P Manuel de Lardizabal, 3, 20018, San Sebastián, Spain.
J Suay AntónIndustrial Systems Engineering and Design Department, Jaime I University (UJI), 12071, Castellón de la Plana, Spain.
Isabel GoñiPolymer Science and Technology Department, University of the Basque Country (UPV/EHU), P Manuel de Lardizabal, 3, 20018, San Sebastián, Spain. isabel.goni@ehu.eus.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Taking into account the influence of Si in osteoblast cell proliferation, a series of sol-gel derived silicon based coating was prepared by controlling the process parameters and varying the different Si-alkoxide precursors molar rate in order to obtain materials able to release Si compounds. For this purpose, methyltrimethoxysilane (MTMOS) and tetraethyl orthosilicate (TEOS) were hydrolysed together and the sol obtained was used to dip-coat the different substrates. The silicon release ability of the coatings was tested finding that it was dependent on the TEOS precursor content, reaching a Si amount value around ninefolds higher for coatings with TEOS than for the pure MTMOS material. To test the effect of this released Si, the in vitro performance of developed coatings was tested with human adipose mesenchymal stem cells finding a significantly higher proliferation and mineralization on the coating with the higher TEOS content. For in vivo evaluation of the biocompatibility, coated implants were placed in the tibia of the rabbit and a histological analysis was performed. The evaluation of parameters such as the bone marrow state, the presence of giant cells and the fibrous capsule proved the biocompatibility of the developed coatings. Furthermore, coated implants seemed to produce a qualitatively higher osteoblastic activity and a higher number of bone spicules than the control (uncoated commercial SLA titanium dental implant).

Indexed as

Dental ImplantsAnimalsBiocompatible MaterialsBone DevelopmentBone MarrowMaterials TestingRabbitsSiliconBiocompatible MaterialsDental ImplantsSilicon

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.