Evidence map›Paper›PMID 26930673›Full record

ArticleIEEE transactions on bio-medical engineering2016

Toward a Portable Cancer Diagnostic Tool Using a Disposable MEMS-Based Biochip.

Hardik J Pandya, Kihan Park, Wenjin Chen, Lauri A Goodell, David J Foran, Jaydev P Desai

Open access · greenAbstract read
In one paragraph

Article in IEEE transactions on bio-medical engineering, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
2.1field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed, 35 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Hardik J Pandya
Kihan Park
Wenjin Chen
Lauri A Goodell
David J Foran
Jaydev P Desai
Rutgers, The State University of New Jersey · USUniversity of Maryland, College Park · USBrigham and Women's Hospital · US

Funding

TRANSCRIPTIONAL PROFILINGP30CA072720 · NCI · UNIV OF MED/DENT NJ-R W JOHNSON MED SCH · PI Chang S Chan · 1997 to 2026
$94.5M
Image Mining for Comparative Analysis of Expression Patterns in Tissue MicroarrayR01LM009239 · NLM · UNIV OF MED/DENT NJ-R W JOHNSON MED SCH · PI FORAN, DAVID J, SALTZ, JOEL H. · 2007 to 2016
$4.5M
Collaborative Systems for Analyzing Tissue MicroarraysR01CA156386 · NCI · UNIV OF MED/DENT NJ-R W JOHNSON MED SCH · PI FORAN, DAVID J · 2010 to 2014
$1.7M
Mechano-Visual Phenotyping of Cancer: From Onset Through Disease ProgressionR01CA161375 · NCI · UNIV OF MARYLAND, COLLEGE PARK · PI DESAI, JAYDEV P., FORAN, DAVID J · 2012 to 2016
$1.6M
NCI NIH HHS P30 CA072720NCI NIH HHS R01 CA156386NCI NIH HHS R01 CA161375NLM NIH HHS R01 LM009239
6 · The paper itself

Abstract

goalThe objective of this study is to design and develop a portable tool consisting of a disposable biochip for measuring electrothermomechanical (ETM) properties of breast tissue.

methodsA biochip integrated with a microheater, force sensors, and electrical sensors is fabricated using microtechnology. The sensor covers the area of 2 mm and the biochip is 10 mm in diameter. A portable tool capable of holding tissue and biochip is fabricated using 3-D printing. Invasive ductal carcinoma and normal tissue blocks are selected from cancer tissue bank in Biospecimen Repository Service at Rutgers Cancer Institute of New Jersey. The ETM properties of the normal and cancerous breast tissues (3-mm thickness and 2-mm diameter) are measured by indenting the tissue placed on the biochip integrated inside the 3-D printed tool.

resultsIntegrating microengineered biochip and 3-D printing, we have developed a portable cancer diagnosis device. Using this device, we have shown a statistically significant difference between cancerous and normal breast tissues in mechanical stiffness, electrical resistivity, and thermal conductivity.

conclusionThe developed cancer diagnosis device is capable of simultaneous ETM measurements of breast tissue specimens and can be a potential candidate for delineating normal and cancerous breast tissue cores. SIGNIFICANCE: The portable cancer diagnosis tool could potentially provide a deterministic and quantitative information about the breast tissue characteristics, as well as the onset and disease progression of the tissues. The tool can be potentially used for other tissue-related cancers.

Indexed as

BreastBreast NeoplasmsEquipment DesignFemaleHumansMicro-Electrical-Mechanical SystemsMicrotechnologyTissue Engineering

Identifiers

PMID26930673
PMCPMC4917475
OpenAlexW2318102414

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.