Evaluating the four-dimensional cone beam computed tomography with varying gantry rotation speed.
Article in The British journal of radiology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
10 citing papers in PubMed.
- Comparative evaluation of 4DCT and 4DCBCT for motion and volume measurement accuracy in a dynamic phantom.Journal of applied clinical medical physics · 2026Article
- Clinical comparison of adaptive 4DCBCT scanning protocols for lung tumor motion assessment.Journal of applied clinical medical physics · 2025Article
- Simulation of a new respiratory phase sorting method for 4D-imaging using optical surface information towards precision radiotherapy.Computers in biology and medicine · 2023Article
- Image guidance for FLASH radiotherapy.Medical physics · 2022Article
- Image quality of 4D in-treatment CBCT acquired during lung SBRT using FFF beam: a phantom study.Radiation oncology (London, England) · 2020Article
- Quantitative evaluation of 4D Cone beam CT scans with reduced scan time in lung cancer patients.Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology · 2019Article
- Evaluation and Clinical Application of a Commercially Available Iterative Reconstruction Algorithm for CBCT-Based IGRT.Technology in cancer research & treatment · 2019Article
- On the improvement of CBCT image quality for soft tissue-based SRS localization.Journal of applied clinical medical physics · 2018Article
- Evaluation of gantry speed on image quality and imaging dose for 4D cone-beam CT acquisition.Radiation oncology (London, England) · 2016Article
- Magnitude, Impact, and Management of Respiration-induced Target Motion in Radiotherapy Treatment: A Comprehensive Review.Journal of medical physicsReview
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors.
Funding
No grant is acknowledged in the PubMed record.
Abstract
objectiveThe purpose of this work was to evaluate the four-dimensional cone beam CT (4DCBCT) imaging with different gantry rotation speed.
methodsAll the 4DCBCT image acquisitions were carried out in Elekta XVI Symmetry™ system (Elekta AB, Stockholm, Sweden). A dynamic thorax phantom with tumour mimicking inserts of diameter 1, 2 and 3 cm was programmed to simulate the respiratory motion (4 s) of the target. 4DCBCT images were acquired with different gantry rotation speeds (36°, 50°, 75°, 100°, 150° and 200° min(-1)). Owing to the technical limitation of 4DCBCT system, average cone beam CT (CBCT) images derived from the 10 phases of 4DCBCT were used for the internal target volume (ITV) contouring. ITVs obtained from average CBCT were compared with the four-dimensional CT (4DCT). In addition, the image quality of 4DCBCT was also evaluated for various gantry rotation speeds using Catphan(®) 600 (The Phantom Laboratory Inc., Salem, NY).
resultsCompared to 4DCT, the average CBCT underestimated the ITV. The ITV deviation increased with increasing gantry speed (-10.8% vs -17.8% for 36° and 200° min(-1) in 3-cm target) and decreasing target size (-17.8% vs -26.8% for target diameter 3 and 1 cm in 200° min(-1)). Similarly, the image quality indicators such as spatial resolution, contrast-to-noise ratio and uniformity also degraded with increasing gantry rotation speed.
conclusionThe impact of gantry rotation speed has to be considered when using 4DCBCT for ITV definition. The phantom study demonstrated that 4DCBCT with slow gantry rotation showed better image quality and less ITV deviation. ADVANCES IN KNOWLEDGE: Usually, the gantry rotation period of Elekta 4DCBCT system is kept constant at 4 min (50° min(-1)) for acquisition, and any attempt of decreasing/increasing the acquisition duration requires careful investigation. In this study, the 4DCBCT images with different gantry rotation speed were evaluated.