Evidence map›Paper›PMID 26912130›Full record

ArticleMicrobial cell factories2016

Easy to use and reliable technique for online dissolved oxygen tension measurement in shake flasks using infrared fluorescent oxygen-sensitive nanoparticles.

David Flitsch, Tobias Ladner, Mihaly Lukacs, Jochen Büchs

Abstract read
In one paragraph

Article in Microbial cell factories, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Photorespiration: The Futile Cycle?Plants (Basel, Switzerland) · 2021
    Review
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

David FlitschBiochemical Engineering, AVT-Aachener Verfahrenstechnik, RWTH Aachen University, Worringerweg 1, 52074, Aachen, Germany. david.flitsch@avt.rwth-aachen.de.
Tobias LadnerBiochemical Engineering, AVT-Aachener Verfahrenstechnik, RWTH Aachen University, Worringerweg 1, 52074, Aachen, Germany. tobias.ladner@avt.rwth-aachen.de.
Mihaly LukacsBiochemical Engineering, AVT-Aachener Verfahrenstechnik, RWTH Aachen University, Worringerweg 1, 52074, Aachen, Germany. mihaly.lukacs@rwth-aachen.de.
Jochen BüchsBiochemical Engineering, AVT-Aachener Verfahrenstechnik, RWTH Aachen University, Worringerweg 1, 52074, Aachen, Germany. jochen.buechs@avt.rwth-aachen.de.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundDespite the progressive miniaturization of bioreactors for screening purposes, shake flasks are still widespread in biotechnological laboratories and industry as cultivation vessels. Shake flasks are often applied as the first or second step in applications such as strain screening or media optimization. Thus, there are ongoing efforts to develop online measurement techniques for shake flasks, to gain as much information as possible about the cultured microbial system. Since dissolved oxygen tension (DOT) is a key experimental parameter, its accurate determination during the course of experiment is critical. Some of the available DOT measurement techniques can lead to erroneous measurements or are very difficult to handle. A reliable and easy to use DOT measurement system, based on suspended oxygen-sensitive nanoparticles, is presented in this work.

resultsIn a cultivation of Kluyveromyces lactis, a new DOT measurement technique via suspended oxygen-sensitive nanoparticles was compared with the conventional DOT measurement via fixed sensor spots. These experiments revealed the main disadvantage of applying sensor spots. With further cultivations of Escherichia coli and Hansenula polymorpha, the new measurement technique was successfully validated. In combination with a RAMOS device, kLa values were determined during the presented cultivations. The determined kLa values are in good agreement with a correlation recently found in the literature.

conclusionsThe presented DOT measurement technique via suspended oxygen-sensitive nanoparticles in shake flasks turned out to be easy to use, robust and reliable under all applied combinations of shaking frequencies and filling volumes. Its applicability as an online monitoring system for cultivations was shown by means of four examples. Additionally, in combination with a RAMOS device, the possibility of experimental kLa determination was successfully demonstrated.

Indexed as

BioreactorsInfrared RaysOnline SystemsCarbonEscherichia coliFluorescenceGreen Fluorescent ProteinsKluyveromycesNanoparticlesOxygenReproducibility of ResultsSolubilityCarbonGreen Fluorescent ProteinsOxygen

Identifiers

PMID26912130
PMCPMC4765216

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.