ArticlePloS one2016
Constraining OCT with Knowledge of Device Design Enables High Accuracy Hemodynamic Assessment of Endovascular Implants.
Article in PloS one, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT06700018 (Development of a Novel Method for Detailed Evaluation of Blood Flow Patterns in Stented Segments and Assessment of Their Role in Stent Thrombosis), which is not on this map. Cited by 13 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Development of a Novel Method for Detailed Evaluation of Blood Flow Patterns in Stented Segments and Assessment of Their Role in Stent Thrombosis
Who cites it
13 citing papers in PubMed, 1 synthesis or guideline pooled it, 21 citations in OpenAlex.
- Automated Coronary Optical Coherence Tomography Feature Extraction with Application to Three-Dimensional Reconstruction.Tomography (Ann Arbor, Mich.) · 2022Pooled it
- Realistic anatomical model reconstruction and high-fidelity flow computation in stented coronary arteries for the analysis of in-stent thrombosis.Frontiers in cardiovascular medicine · 2026Article
- Article
- Angiography and optical coherence tomography derived shear stress: are they equivalent in my opinion?The international journal of cardiovascular imaging · 2023Article
- Three dimensional reconstruction of coronary artery stents from optical coherence tomography: experimental validation and clinical feasibility.Scientific reports · 2021Article
- The Evolution of Data Fusion Methodologies Developed to Reconstruct Coronary Artery Geometry From Intravascular Imaging and Coronary Angiography Data: A Comprehensive Review.Frontiers in cardiovascular medicine · 2020Review
- Establishment of an Automated Algorithm Utilizing Optical Coherence Tomography and Micro-Computed Tomography Imaging to Reconstruct the 3-D Deformed Stent Geometry.IEEE transactions on medical imaging · 2019Article
- Quantification of thrombus formation in malapposed coronary stents deployed in vitro through imaging analysis.Journal of biomechanics · 2018Article
- Patient-Specific Modeling of Stented Coronary Arteries Reconstructed from Optical Coherence Tomography: Towards a Widespread Clinical Use of Fluid Dynamics Analyses.Journal of cardiovascular translational research · 2018Review
- Polymeric endovascular strut and lumen detection algorithm for intracoronary optical coherence tomography images.Journal of biomedical optics · 2018Article
- Automated Segmentation of Bioresorbable Vascular Scaffold Struts in Intracoronary Optical Coherence Tomography Images.International Conference on Bioinformatics and Biomedical Engineering : [proceedings]. International Conference on Bioinformatics and Biomedical Engineering · 2017Article
- Article
- Computational Model of Drug-Coated Balloon Delivery in a Patient-Specific Arterial Vessel with Heterogeneous Tissue Composition.Cardiovascular engineering and technology · 2016Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundStacking cross-sectional intravascular images permits three-dimensional rendering of endovascular implants, yet introduces between-frame uncertainties that limit characterization of device placement and the hemodynamic microenvironment. In a porcine coronary stent model, we demonstrate enhanced OCT reconstruction with preservation of between-frame features through fusion with angiography and a priori knowledge of stent design. METHODS AND
resultsStrut positions were extracted from sequential OCT frames. Reconstruction with standard interpolation generated discontinuous stent structures. By computationally constraining interpolation to known stent skeletons fitted to 3D 'clouds' of OCT-Angio-derived struts, implant anatomy was resolved, accurately rendering features from implant diameter and curvature (n = 1 vessels, r2 = 0.91, 0.90, respectively) to individual strut-wall configurations (average displacement error ~15 μm). This framework facilitated hemodynamic simulation (n = 1 vessel), showing the critical importance of accurate anatomic rendering in characterizing both quantitative and basic qualitative flow patterns. Discontinuities with standard approaches systematically introduced noise and bias, poorly capturing regional flow effects. In contrast, the enhanced method preserved multi-scale (local strut to regional stent) flow interactions, demonstrating the impact of regional contexts in defining the hemodynamic consequence of local deployment errors.
conclusionFusion of planar angiography and knowledge of device design permits enhanced OCT image analysis of in situ tissue-device interactions. Given emerging interests in simulation-derived hemodynamic assessment as surrogate measures of biological risk, such fused modalities offer a new window into patient-specific implant environments.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.