ArticleJournal of neural engineering2016
Temporal properties of network-mediated responses to repetitive stimuli are dependent upon retinal ganglion cell type.
Article in Journal of neural engineering, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
23 citing papers in PubMed.
- Adaptation of visual responses in degeneratingFrontiers in neuroscience · 2026Article
- Asymmetric activation of retinal ON and OFF pathways by AOSLO raster-scanned visual stimuli.Biomedical optics express · 2025Article
- Machine Learning Techniques for Simulating Human Psychophysical Testing of Low-Resolution Phosphene Face Images in Artificial Vision.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2025Article
- Quantitative analyses of how optimally heterogeneous neural codes maximize neural information in jittery transmission environments.Scientific reports · 2024Article
- Article
- Electrically-evoked responses for retinal prostheses are differentially altered depending on ganglion cell types in outer retinal neurodegeneration caused byFrontiers in cellular neuroscience · 2023Article
- Retinal ganglion cell desensitization is mitigated by varying parameter constant excitation pulse trains.Frontiers in cellular neuroscience · 2022Article
- Correlated Activity in the Degenerate Retina Inhibits Focal Response to Electrical Stimulation.Frontiers in cellular neuroscience · 2022Article
- Artificial Visual Information Produced by Retinal Prostheses.Frontiers in cellular neuroscience · 2022Review
- Stage-Dependent Changes of Visual Function and Electrical Response of the Retina in theFrontiers in cellular neuroscience · 2022Article
- Fabrication of High-Density Out-of-Plane Microneedle Arrays with Various Heights and Diverse Cross-Sectional Shapes.Nano-micro letters · 2021Article
- The impact of synchronous versus asynchronous electrical stimulation in artificial vision.Journal of neural engineering · 2021Review
- Spiking Characteristics of Network-Mediated Responses Arising in Direction-Selective Ganglion Cells of Rabbit and Mouse Retinas to Electric Stimulation for Retinal Prostheses.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2021Article
- Editorial for the Special Issue on Micro/Nanofabrication for Retinal Implants.Micromachines · 2020Article
- Retinal Degeneration Reduces Consistency of Network-Mediated Responses Arising in Ganglion Cells to Electric Stimulation.IEEE transactions on neural systems and rehabilitation engineering : a publication of the IEEE Engineering in Medicine and Biology Society · 2020Article
- Probing and predicting ganglion cell responses to smooth electrical stimulation in healthy and blind mouse retina.Scientific reports · 2020Article
- Stimulation Strategies for Improving the Resolution of Retinal Prostheses.Frontiers in neuroscience · 2020Review
- Response of Mouse Visual Cortical Neurons to Electric Stimulation of the Retina.Frontiers in neuroscience · 2019Article
- Direct measurement of bipolar cell responses to electrical stimulation in wholemount mouse retina.Journal of neural engineering · 2018Article
- Electric stimulus duration alters network-mediated responses depending on retinal ganglion cell type.Journal of neural engineering · 2018Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
2 authors.
Funding
Abstract
objectiveTo provide artificially-elicited vision that is temporally dynamic, retinal prosthetic devices will need to repeatedly stimulate retinal neurons. However, given the diversity of physiological types of retinal ganglion cells (RGCs) as well as the heterogeneity of their responses to electric stimulation, temporal properties of RGC responses have not been adequately investigated. Here, we explored the cell type dependence of network-mediated RGC responses to repetitive electric stimulation at various stimulation rates. APPROACH: We examined responses of ON and OFF types of RGCs in the rabbit retinal explant to five consecutive stimuli with varying inter-stimulus intervals (10-1000 ms). Each stimulus was a 4 ms long monophasic sinusoidal cathodal current, which was applied epiretinally via a conical electrode. Spiking activity of targeted RGCs was recorded using a cell-attached patch electrode. MAIN
resultsON and OFF cells had distinct responses to repetitive stimuli. Consistent with earlier studies, OFF cells always generated reduced responses to subsequent stimuli compared to responses to the first stimulus. In contrast, a new stimulus to ON cells suppressed all pending/ongoing responses from previous stimuli and initiated its own response that was remarkably similar to the response from a single stimulus in isolation. This previously unreported 'reset' behavior was observed exclusively and consistently in ON cells. These contrasts between ON and OFF cells created a range of stimulation rates (4-7 Hz) that maximized the ratio of the responses arising in ON versus OFF cells. SIGNIFICANCE: Previous clinical testing reported that subjects perceive bright phosphenes (ON responses) and also prefer stimulation rates of 5-7 Hz. Our results suggest that responses of ON cells are weak at high rates of stimulation (> ∼7 Hz) due to the reset while responses of OFF cells are strong at low rates (< ∼4 Hz) due to reduced desensitization, both reducing the ratio of ON to OFF responses. In combination with previous results indicating that responses in ON cells more closely match physiological patterns (Im and Fried 2015 J. Physiol. 593 3577-96), our results offer a potential reason for the user preference of intermediate rates (5-7 Hz).
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.