Evidence map›Paper›PMID 26904504›Full record

ArticleFrontiers in oncology2016

Plan Quality and Treatment Efficiency for Radiosurgery to Multiple Brain Metastases: Non-Coplanar RapidArc vs. Gamma Knife.

Haisong Liu, David W Andrews, James J Evans, Maria Werner-Wasik, Yan Yu, Adam Paul Dicker, Wenyin Shi

Abstract read
In one paragraph

Article in Frontiers in oncology, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 44 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
44citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

44 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Observational
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Review
  11. Planning issues on linac-based stereotactic radiotherapy.World journal of clinical cases · 2022
    Review
  12. Review
  13. Article
  14. Article
  15. Review
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Haisong LiuDepartment of Radiation Oncology, Thomas Jefferson University , Philadelphia, PA , USA.
David W AndrewsDepartment of Neurological Surgery, Thomas Jefferson University , Philadelphia, PA , USA.
James J EvansDepartment of Neurological Surgery, Thomas Jefferson University , Philadelphia, PA , USA.
Maria Werner-WasikDepartment of Radiation Oncology, Thomas Jefferson University , Philadelphia, PA , USA.
Yan YuDepartment of Radiation Oncology, Thomas Jefferson University , Philadelphia, PA , USA.
Adam Paul DickerDepartment of Radiation Oncology, Thomas Jefferson University , Philadelphia, PA , USA.
Wenyin ShiDepartment of Radiation Oncology, Thomas Jefferson University , Philadelphia, PA , USA.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesThis study compares the dosimetry and efficiency of two modern radiosurgery [stereotactic radiosurgery (SRS)] modalities for multiple brain metastases [Gamma Knife (GK) and LINAC-based RapidArc/volumetric modulated arc therapy], with a special focus on the comparison of low-dose spread.

methodsSix patients with three or four small brain metastases were used in this study. The size of targets varied from 0.1 to 10.5 cc. SRS doses were prescribed according to the size of lesions. SRS plans were made using both Gamma Knife(®) Perfexion and a single-isocenter, multiple non-coplanar RapidArc(®). Dosimetric parameters analyzed included RTOG conformity index (CI), gradient index (GI), 12 Gy isodose volume (V 12Gy) for each target, and the dose "spread" (Dspread) for each plan. Dspread reflects SRS plan's capability of confining radiation to within the local vicinity of the lesion and to not spread out to the surrounding normal brain tissues. Each plan has a dose (Dspread), such that once dose decreases below Dspread (on total tissue dose-volume histogram), isodose volume starts increasing dramatically. Dspread is defined as that dose when volume increase first exceeds 20 cc/0.1 Gy dose decrease.

resultsRapidArc SRS has smaller CI (1.19 ± 0.14 vs. 1.50 ± 0.16, p < 0.001) and larger GI (4.77 ± 1.49 vs. 3.65 ± 0.98, p < 0.01). V 12Gy results were comparable (2.73 ± 1.38 vs. 3.06 ± 2.20 cc, p = 0.58). Moderate to lower dose spread, V6, V4.5, and V3, were also equivalent. GK plans achieved better very low-dose spread (≤3 Gy) and also had slightly smaller Dspread, 1.9 vs. 2.5 Gy. Total treatment time for GK is estimated between 60 and 100 min. GK treatments are between 3 and 5 times longer compared to RapidArc treatment techniques.

conclusionDosimetric parameters reflecting prescription dose conformality (CI), dose fall off (GI), radiation necrosis indicator (V 12Gy), and dose spread (Dspread) were compared between GK SRS and RapidArc SRS for multi-mets. RapidArc plans have smaller CI but larger GI. V 12Gy are comparable. GK appears better at reducing only very low-dose spread (<3 Gy). The treatment time of RapidArc SRS is significantly reduced compared to GK SRS.

Indexed as

brain metastasisGamma KnifeRapidArcSRSVMAT

Identifiers

PMID26904504
PMCPMC4749694

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.