Evidence map›Paper›PMID 26897005›Full record

ArticleThe international journal of cardiovascular imaging2016

Diagnostic accuracy of sub-mSv prospective ECG-triggering cardiac CT in young infant with complex congenital heart disease.

Wei Gao, Yu Min Zhong, Ai Min Sun, Qian Wang, Rong Zhen Ouyang, Li Wei Hu, Han Sheng Qiu, Shi Yu Wang, Jian Ying Li

Abstract read
PubMed Publisher
In one paragraph

Article in The international journal of cardiovascular imaging, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers.

0numbers the graph read from it
0cells of the map it votes in
14citing papers in PubMed
2.3field-weighted citation impact, top 13% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

14 citing papers in PubMed, 30 citations in OpenAlex.

  1. Trial
  2. Trial
  3. Article
  4. Review
  5. Article
  6. Review
  7. Article
  8. Review
  9. Article
  10. Article
  11. Review
  12. Article
  13. Article
  14. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 3 institutions in 1 country.

Wei GaoDepartment of Pediatric Cardiology, Shanghai Children's Medical Center, Shanghai Jiao Tong University, School of Medicine, Shanghai, P.R. China.
Yu Min ZhongDiagnostic Imaging Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University, School of Medicine, Shanghai, P.R. China. zyumin2002@163.com.
Ai Min SunDiagnostic Imaging Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University, School of Medicine, Shanghai, P.R. China.
Qian WangDiagnostic Imaging Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University, School of Medicine, Shanghai, P.R. China.
Rong Zhen OuyangDiagnostic Imaging Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University, School of Medicine, Shanghai, P.R. China.
Li Wei HuDiagnostic Imaging Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University, School of Medicine, Shanghai, P.R. China.
Han Sheng QiuDiagnostic Imaging Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University, School of Medicine, Shanghai, P.R. China.
Shi Yu WangDiagnostic Imaging Center, Shanghai Children's Medical Center, Shanghai Jiao Tong University, School of Medicine, Shanghai, P.R. China.
Jian Ying LiCT Research Center, GE Healthcare, Beijing, P.R. China.
Shanghai Children's Medical Center · CNShanghai Jiao Tong University · CNUnited Imaging Healthcare (China) · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

To explore the clinical value and evaluate the diagnostic accuracy of sub-mSv low-dose prospective ECG-triggering cardiac CT (CCT) in young infants with complex congenital heart disease (CHD). A total of 102 consecutive infant patients (53 boys and 49 girls with mean age of 2.9 ± 2.4 m and weight less than 5 kg) with complex CHD were prospectively enrolled. Scans were performed on a 64-slice high definition CT scanner with low dose prospective ECG-triggering mode and reconstructed with 80 % adaptive statistical iterative reconstruction algorithm. All studies were performed during free breathing with sedation. The subjective image quality was evaluated by 5-point grading scale and interobserver variability was calculated. The objective image noise (standard deviation, SD) and contrast to noise ratio (CNR) was calculated. The effective radiation dose from the prospective ECG-triggering mode was recorded and compared with the virtual conventional retrospective ECG-gating mode. The detection rate for the origin of coronary artery was calculated. All patients also underwent echocardiography before CCT examination. 81 patients had surgery and their preoperative CCT and echocardiography findings were compared with the surgical results and sensitivity, specificity, positive and negative predictive values and accuracy were calculated for separate cardiovascular anomalies. Heart rates were 70-161 beats per minute (bpm) with mean value of 129.19 ± 14.52 bpm. The effective dose of 0.53 ± 0.15 mSv in the prospective ECG-triggering cardiac CT was lower than the calculated value in a conventional retrospective ECG-gating mode (2.00 ± 0.35 mSv) (p < 0.001). The mean CNR and SD were 28.19 ± 13.00 and 15.75 ± 3.61HU, respectively. The image quality scores were 4.31 ± 0.36 and 4.29 ± 0.41 from reviewer 1 and 2 respectively with an excellent agreement between them (Kappa = 0.85). The detection rate for the origins of the left and right coronary arteries was 96 and 90 %, respectively. The detection rates of the origins of left coronary artery and right coronary artery in all cases were 96 % (78/81) and 90 % (73/81), respectively. Twenty cases of conotruncal anomalies and ALCAPA were validated surgically and the accuracy of cardiac CT diagnosis was 95 % (19/20). The overall deformity based sensitivity, specificity, positive predictive value and negative predictive value were 94.0.1, 99.9, 98.6, 99.5 % respectively, by CCT, and 88.2, 99.9, 97.8, 99.0 %, respectively, by echocardiography. Prospective ECG-triggering CCT with sub-mSv effective dose provides excellent imaging quality and high diagnostic accuracy for young infants with complex CHD.

Indexed as

Cardiac-Gated Imaging TechniquesComputed Tomography AngiographyCoronary AngiographyElectrocardiographyMultidetector Computed TomographyRadiation DosageRadiation ExposureAge FactorsCoronary VesselsFemaleHeart Defects, CongenitalHumansInfantInfant, NewbornMaleObserver VariationCardiac CT angiographyCongenital heart diseaseProspective ECG-triggeringRadiation exposure

Identifiers

PMID26897005
OpenAlexW2283917942

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.