Evidence map›Paper›PMID 26894335›Full record

ArticleJournal of applied clinical medical physics2016

Comparison of volumetric-modulated arc therapy and dynamic conformal arc treatment planning for cranial stereotactic radiosurgery.

Jessica Molinier, Christine Kerr, Sebastien Simeon, Norbert Ailleres, Marie Charissoux, David Azria, Pascal Fenoglietto

Abstract readComparative Study
In one paragraph

Article in Journal of applied clinical medical physics, 2016. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 20 papers.

0numbers the graph read from it
0cells of the map it votes in
20citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

20 citing papers in PubMed.

  1. Trial
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Review
  9. Article
  10. Article
  11. Article
  12. Article
  13. Article
  14. A simple knowledge-based tool for stereotactic radiosurgery pre-planning.Journal of applied clinical medical physics · 2019
    Article
  15. Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Dosimetric comparison of dynamic conformal arc integrated with segment shape optimization and variable dose rate versus volumetric modulated arc therapy for liver SBRT.Reports of practical oncology and radiotherapy : journal of Greatpoland Cancer Center in Poznan and Polish Society of Radiation Oncology
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors.

Jessica MolinierICM Val d'Aurelle. jessica.molinier@icm.unicancer.fr.
Christine Kerr
Sebastien Simeon
Norbert Ailleres
Marie Charissoux
David Azria
Pascal Fenoglietto

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The aim was to analyze arc therapy techniques according to the number and position of the brain lesions reported by comparing dynamic noncoplanar conformal arcs (DCA), two coplanar full arcs (RAC) with volumetric-modulated arc therapy (VMAT), multiple noncoplanar partial arcs with VMAT (RANC), and two full arcs with VMAT and 10° table rotation (RAT). Patients with a single lesion (n= 10), multiple lesions (n = 10) or a single lesion close to organs at risk (n = 5) and previously treated with DCA were selected. For each patient, the DCA treatment was replanned with all VMAT techniques. All DCA plans were compared with VMAT plans and evaluated in regard to the different quality indices and dosimetric parameters. For single lesion, homogeneity index (HI) better results were found for the RANC technique (0.17 ± 0.05) compared with DCA procedure (0.27± 0.05). Concerning conformity index (CI), the RAT technique gave higher and better values (0.85 ± 0.04) compared with those obtained with the DCA technique (0.77 ± 0.05). DCA improved healthy brain protection (8.35 ± 5.61 cc vs. 10.52 ± 6.40 cc for RANC) and reduced monitor unit numbers (3046 ± 374 MU vs. 4651 ± 736 for RANC), even if global room occupation was higher. For multiple lesions, VMAT techniques provided better HI (0.16) than DCA (0.24 ± 0.07). The CI was improved with RAT (0.8 ± 0.08 for RAT vs. 0.71 ± 0.08 for DCA). The V10Gy healthy brain was better protected with DCA (9.27 ± 4.57 cc). Regarding the MU numbers: RANC < RAT< RAC < DCA. For a single lesion close to OAR, RAT achieved high degrees of homogeneity (0.27 ± 0.03 vs. 0.53 ± 0.2 for DCA) and conformity (0.72± 0.06vs. 0.56 ± 0.13 for DCA) while sparing organs at risk (Dmax = 12.36 ± 1.05Gyvs. 14.12 ± 0.59 Gy for DCA, and Dmean = 3.96 ± 3.57Gyvs. 4.72 ± 3.28Gy for DCA). On the other hand, MU numbers were lower with DCA (2254 ± 190 MUvs. 3438 ± 457 MU for RANC) even if overall time was inferior with RAC. For a single lesion, DCA provide better plan considering low doses to healthy brain even if quality indexes are better for the others techniques. For multiple lesions, RANC seems to be the best compromise, due to the ability to deliver a good conformity and homogeneity plan while sparing healthy brain tissue. For a single lesion close to organs at risk, RAT is the most appropriate technique.

Indexed as

RadiosurgeryAnimalsBrain NeoplasmsBreast NeoplasmsFemaleHumansLung NeoplasmsOrgans at RiskPrognosisRadiometryRadiotherapy, ConformalRadiotherapy DosageRadiotherapy, Intensity-ModulatedRadiotherapy Planning, Computer-AssistedRats

Identifiers

PMID26894335
PMCPMC5690199

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.